4.16

Sense Subsystem - Sweep

[3Pi controller only]

This subsystem controls the measurement current range, the data acquire sequence, and
the harmonic measurement window of the AC source.

Subsystem Syntax

SENSe
:SWEep

:OFFSet

Define trigger points relative to the start of
the digitizer data record

:TINTerval?

Query the digitizer sample spacing

SENSe:SWEep:OFFSet

This command defines the trigger point relative to the start of the returned data record when
an acquire trigger is used. The values can range from:

MX Series I:

-104 msec to 1000 msec in a single-phase configuration and from -312

msec to 1000 msec in a three-phase configuration.

MX Series II and RS Series: -42 msec to 1000 msec in a single-phase configuration and
from -128 msec to 1000 msec in a three-phase configuration.

When the value specified is negative (less than 0 msec), the values in the beginning of the
data record represent samples taken prior to the actual trigger moment.

Command Syntax

SENSe:SWEep:OFFSet

Parameters

MX Series I:

-104 to 1000 for single phase configuration

-312 to 1000 for three phase configuration

MX/RS Series II:-42 to 1000 for single phase configuration
-128 to 1000 for three phase configuration

*RST Value

0

Examples SENS:SWE:OFFS

-5

Query Syntax

SENSe:SWEep:OFFSet?

Returned Parameters

Related Commands

SENS:SWE:TINT?

MEAS:ARR