DO160:NORMal:FREQuency:MODulation

This command will cause output frequency modulation. The level of modulation is the
function of the rate of modulation. Refer to Figure 9-5 in the User Manual. The command
parameter is the rate of modulation in Hz.

Command Syntax

DO160:NORMal:FREQuency:MODulation

Parameters
Examples DO160:NORM:FREQ:MOD

0.1

Query Syntax

DO160:NORM:FREQ:MOD?

Returned Parameters

DO160:NORMal:FREQuency:TRANsient

This command applies to Group 1 only for the the Eurocae standard. Refer to Table 5 in the
User Manual.

Command Syntax

DO160:NORMal:FREQuency:TRANsient

Parameters none
Examples DO160:NORM:FREQ:TRAN
Query Syntax

none

Returned Parameters

none

DO160:NORMal:FREQuency:VARiation

This command applies to Group 2 and 3 only for the Eurocae standard. Refer to Table 6 in
the User Manual.

Command Syntax

DO160:NORMal:FREQuency:VARiation

Parameters none
Examples DO160:NORM:FREQ:VAR
Query Syntax

none

Returned Parameters

none

DO160:EMERgency:VOLT_FREQ:MINimum

This command will set the voltage and frequency to the minimum level for the emergency
operation.

Command Syntax

DO160:EMERgency l:VOLT_FREQ:MINimum

Parameters none
Examples DO160:EMER:VOLT_FREQ:MIN
Query Syntax

none