DO160:NORMal:FREQuency:MODulation
This command will cause output frequency modulation. The level of modulation is the
function of the rate of modulation. Refer to Figure 9-5 in the User Manual. The command
parameter is the rate of modulation in Hz.
Command Syntax
DO160:NORMal:FREQuency:MODulation
Parameters
Examples DO160:NORM:FREQ:MOD
0.1
Query Syntax
DO160:NORM:FREQ:MOD?
Returned Parameters
DO160:NORMal:FREQuency:TRANsient
This command applies to Group 1 only for the the Eurocae standard. Refer to Table 5 in the
User Manual.
Command Syntax
DO160:NORMal:FREQuency:TRANsient
Parameters none
Examples DO160:NORM:FREQ:TRAN
Query Syntax
none
Returned Parameters
none
DO160:NORMal:FREQuency:VARiation
This command applies to Group 2 and 3 only for the Eurocae standard. Refer to Table 6 in
the User Manual.
Command Syntax
DO160:NORMal:FREQuency:VARiation
Parameters none
Examples DO160:NORM:FREQ:VAR
Query Syntax
none
Returned Parameters
none
DO160:EMERgency:VOLT_FREQ:MINimum
This command will set the voltage and frequency to the minimum level for the emergency
operation.
Command Syntax
DO160:EMERgency l:VOLT_FREQ:MINimum
Parameters none
Examples DO160:EMER:VOLT_FREQ:MIN
Query Syntax
none