BPS / MX / RS Series SCPI Programming Manual

AMETEK Programmable Power

Manual P/N 7003-961 Rev. AA

181

IEC413:MCURve:LEVel

This command will set the levels for the meister curve test. The class must be set prior to
this command. The IEC413:STATe must be in the off position and the user class must be
selected to accept the command. The command will accept a sequence of five data level
parameters. The first two have a range for 0 to 20. These two parameters set the test level
in % for the frequency range 0.33 to 2 x f1 and 2 to 10 x f1 respectively. The last three
parameters set the test levels for 10 to 20 x f1and 20 to 40 x f1 in n/f. These values for n
can be up to 10,000. All are expressed in % of U1. Note that the IEC 61000-4-13 shows only
two frequency ranges in the Meister curve table but the –413 option separates the third
range in two ranges resulting in 5 instead of 4 parameters. Set both parameter 3 and 4 to
the same value to match the IEC standard table. (See table for reference).

IEC

Frequency
Range

Class X
Test Levels

-413
Option

Frequency
Range

Class X
Test Levels

0.33xf1 to 2xf1

Open

0.33xf1 to 2xf1 Parameter

1

2xf1 to 10xf1

Open

2xf1 to 10xf1

Parameter 2

10xf1 to 20xf1

Open

10xf1 to 15xf1

Parameter 3

15xf1 to 20xf1

Parameter 4

20xf1 to 40xf1

Open

20xf1 to 40xf1

Parameter 5

Command Syntax

IEC413:MCURve:LEVel

Parameters

0 to 20, 0 to 10,000

Examples IEC413:MCURve:LEVel 10,5,4500,4500,5000
Query Syntax

IEC413:MCURve:LEVel?

Returned Parameters

IEC413:MCURve:DWELl

This command will set the dwell time in seconds for the meister curve test. The class must
be selected prior to this command. Query with min and max to find the range of dwell time.
The default is 10 seconds. This value may not be enough to cover the 5 minutes required by
the test for each range. The user must coordinate the step size with the dwell time to
generate the test period for each frequency range.

Command Syntax

IEC413:MCURve:DWELl

Parameters
Examples IEC413:MCURve:DWEL

20

Query Syntax

IEC413:MCURve:DWEL?

Returned Parameters

IEC413:MCURve:PAUSe

This command will set the pause time in seconds. This is the time between tests when
RUN:ALL is selected The class must be selected prior to this command. Query with min
and max to find the range of the dwell time. When the selected GROUP is MCURve, the
pause should normally be set to 0 as no pause is required for this test. If a pause value other
than zero is set, the interharmonic levels during the pause period will be zero.