beautypg.com

AMETEK BPS Series Programming Manual User Manual

Page 107

background image

BPS / MX / RS Series SCPI Programming Manual

AMETEK Programmable Power

Manual P/N 7003-961 Rev. AA

107

4.22

Source Subsystem - Voltage

This subsystem programs the output voltage of the AC/DC power source.

Subsystem Syntax

[SOURce:]
VOLTage

:ALC ON | OFF | REG

Sets Automatic Level Control mode

[:LEVel]
[:IMMediate]

[:AMPLitude]

Sets the AC rms voltage amplitude

[:AC]

:DC

:OFFSet

Set the DC offset value in AC+DC mode

:TRIGgered

[:AMPLitude]

Sets the transient voltage amplitude

:MODE

Sets the voltage mode
(FIX|STEP|PULS|LIST)

:HIGH

Sets the voltage programming limits

:RANGe

[:LEVel]

Sets

the

voltage

range

:SENSe

[:SOURce]

INTernal

|

EXTernal

Sets voltage sense source

:SLEW

[:IMMediate] | MAXimum

Sets the voltage slew rate

:MODE

Sets voltage slew mode
(FIX|STEP|PULS|LIST)

:TRIGgered

[:AMPLitude] | MAXimum

Sets the transient voltage slew rate

VOLTage:ALC

Phase Selectable

This command enables or disables the automatic voltage level control mode. If ALC is on,
the output voltage of the power source is continuously adjusted based on the voltage
measurement data acquired by the controller's measuremet system. This results in
increased output accuracy and load regulation. If regulation cannot be maintained, an output
voltage fault error is generated and the output is turned off. The regulate mode (REG) may
be set to enable ALC mode but disable the output volt fault error if load regulation cannot be
maintained.

Note that for the MX15-1Pi, MX30-3Pi, MX45-3Pi, RS and BPS Series this mode is coupled
with the OUTP:IMP commands as the ALC mode and the programmable impedance
functions are mutually exclusive. Attempting to enable one while the other is active will result
in a command error. The ALC mode is also inactive during transient execution, even if it is
enabled.

Command Syntax

[SOURce:]VOLTage:ALC

Parameters

0 | OFF | 1 | ON | 2 | REG

Unit

V/S (volts per second)

*RST Value

0

Examples VOLT:ALC

1

Query Syntax

[SOURce:]VOLTage:ALC?

Returned Parameters

0 | 1 | 2

Related Commands

OUTP:IMP:STAT