TRIGger[:TRANSient]:SOURce

This command will determine the source of the trigger event for the transient. The following
sources are available:

• IMMediate Triggering occurs as soon as the INIT command is received.
• BUS

Triggering occurs following the INIT command after receiving the *TRG

command or a Group Execute Trigger (GET) IEEE signal.

• EXTernal Triggering occurs when an external trigger input is received.

Command Syntax

TRIGger[:TRANSient]:SOURce

Parameters

IMMediate | BUS | EXT

*RST Value

IMMediate

Examples TRIG:SOUR

BUS

Related Commands

ABOR

TRIGger:COUNt

This command determines whether the phase synchronization is accomplished at the
begining of the transient list or pulse for every COUNt or at the begining of the transient for
the first count only. It accepts the following parameters.

• NONe

Synchronization is accomplished once

• ALL

Synchronization is accomplished for every count.

Command Syntax

TRIGger:COUNt ALL

TRIGger:COUNt

NONE

Parameters ALL,

NONE

*RST Value

NONE

Examples TRIG:COUN

ALL

TRIG:COUN

NONE

Query Syntax

TRIG:COUN?

Returned Parameters

Related Commands

ABOR TRIG

TRIG:DEL

TRIG:SYNC

TRIG:SYNC:PHAS

INIT

INIT:CONT *TRG WAI