BPS / MX / RS Series SCPI Programming Manual
AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA
47
4.2.7
Output - AC Voltage
CALibrate[:SOURce]:VOLTage[:AC]:LRANge[:FSCale]
This command will result in the calibration coefficent being calculated for the AC full scale
output voltage at the low voltage range.
Command Syntax
CALibrate:VOLTage:LRANge
Parameters
Examples CAL:VOLT:LRAN
120
Query Syntax
CALibrate:VOLTage:LRANge?
Returned Parameters
Related Commands
CAL:VOLT:LRAN:ZERO CAL:VOLT:LRAN:HFR
CALibrate[:SOURce]:VOLTage[:AC]:LRANge:ZERO
This command will set the calibration coefficent for the output voltage offset at the low
voltage range.
Command Syntax
CALibrate:VOLTage:LRANge:ZERO
Parameters
Examples
CAL:VOLT:LRAN:ZERO +10
Query Syntax
CALibrate:VOLTage:LRANge:ZERO?
Returned Parameters
Related Commands
CAL:VOLT:LRAN CAL:VOLT:LRAN:HFR
CALibrate[:SOURce]:VOLTage[:AC]:LRANge:HFRequency
This command will set the calibration coefficent for the AC full scale output voltage at the low
voltage range and at high output frequency
Command Syntax
CALibrate:VOLTage:LRANge:HFRequency
Parameters
Examples CAL:VOLT:LRAN:HFRequency
+10
Query Syntax
CALibrate:VOLTage:LRANge:HFRequency?
Returned Parameters
Related Commands
CAL:VOLT:LRAN CAL:VOLT:LRAN:ZERO
CALibrate[:SOURce]:VOLTage[:AC]:HRANge[:FSCale]
This command will result in the calibration coefficent being calculated for the AC full scale
output voltage at the high voltage range.
Command Syntax
CALibrate:VOLTage:HRANge
Parameters
Examples CAL:VOLT:HRAN
-2
Query Syntax
CALibrate:VOLTage:HRANge?
Returned Parameters
<
Related Commands
CAL:VOLT:HRAN:ZERO CAL:VOLT:HRAN:HFR