BPS / MX / RS Series SCPI Programming Manual
AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA
109
VOLTage:MODE
Phase Selectable
This command determines how the output voltage is controlled during a triggered output
transient. The choices are:
FIXed
The voltage is unaffected by a triggered output transient.
STEP
The voltage is programmed to the value set by VOLTage:TRIGgered when
a triggered transient occurs.
PULSe
The voltage is changed to the value set by VOLTage:TRIGgered for a
duration determined by the pulse commands.
LIST
The voltage is controlled by the voltage list when a triggered transient
occurs.
Command Syntax
[SOURce:]VOLTage:MODE
Parameters
FIXed | STEP | PULSe | LIST
*RST Value
FIX
Examples
VOLT:MODE LIST
VOLT:MODE FIX
Query Syntax
[SOURce:]VOLTage:MODE?
Returned Parameters
Related Commands
VOLT:TRG
VOLT
VOLTage:HIGH
This command programs the maximum rms voltage that the power source will accept. The
maximum value will be the lower of this value or the voltage range.
Command Syntax
[SOURce:]VOLTage:HIGH
Parameters
0 to maximum voltage range specified by the LIMit:VOLTage
command
Unit
V (rms voltage)
*RST Value
no change
Examples VOLT:HIGH
250
Query Syntax
[SOURce:]VOLTage:HIGH?
Returned Parameters
Related Commands
[SOUR:]VOLT:LEV
VOLTage:RANGe[:LEVel]
This command sets the voltage range of the power source. On the MX/RS/BPS Series, up to
three voltage ranges are available:
• 150 V AC or 200 V DC range
• 300 V AC or 400 V DC range
• 400 V AC or other (-XV) range
The LIM:VOLT? Query may be used to determine which AC voltage ranges are available to
select. This command always returns the AC voltage range values. When in DC mode,
used 200 iso 150 or 400 iso 300 to select the low and high DC voltage range. Sending a
parameter other than these will not be accepted.