beautypg.com

Verifying installation, Mechanical checks, System cable checks – Adept s650H Quattro User Manual

Page 74: User-supplied safety equipment checks

background image

Chapter 5 - System Operation

74

Adept Quattro s650 Robot User’s Guide, Rev B

Verifying Installation

Verifying that the system is correctly installed and that all safety equipment is working
correctly is an important process. Before using the robot, make the following checks to
ensure that the robot and controller have been properly installed.

Mechanical Checks

• Verify that the robot is mounted level and that all fasteners are properly installed

and tightened.

• Verify that any platform tooling is properly installed.

• Verify that the platform is clocked

• Verify that all other peripheral equipment is properly installed such that it is safe

to turn on power to the robot system.

System Cable Checks

Verify the following connections:

• Front Panel connected to the SmartController.

• Optional T1 connected to the SmartController, via the MCP adapter cable, or a

loop-back dongle installed.

• User-supplied 24 VDC power connected to the controller.

• User-supplied ground wire installed between the SmartController and ground.

• One end of the IEEE 1394 cable installed into SmartServo port 1.1 on the

SmartController, and the other end installed into SmartServo port 1 on the robot
interface panel.

• XSYS cable installed between the robot interface panel XSLV safety interlock

connector and XSYS connector on the SmartController, and latching screws
tightened.

• User-supplied 24 VDC power connect to the robot 24 VDC connector.

• User-supplied 200/240 VAC power connect to the robot 200/240 VAC connector.

User-Supplied Safety Equipment Checks

Verify that all user-supplied safety equipment and E-Stop circuits are installed correctly.

DANGER:

After installing the robot, you must test it before

you use it for the first time. Failure to do this could cause
death, serious injury, or equipment damage.