beautypg.com

Xio output signals, Xio output specifications – Adept s650H Quattro User Manual

Page 71

background image

Using Digital I/O on Robot XIO Connector

Adept Quattro s650 Robot User’s Guide, Rev B

71

XIO Output Signals

The eight digital outputs share a common, high side (sourcing) Driver IC. The Driver is
designed to supply any kind of load with one side connected to ground. It is designed for
a range of user-provided voltages from 10 to 24 VDC, and each channel is capable of up to
0.7 A of current. This Driver has overtemperature protection, current limiting, and
shorted load protection. In the event of an output short or other overcurrent situation, the
affected output of the Driver IC turns off and back on automatically to reduce the
temperature of the IC. The Driver draws power from the primary 24 VDC input to the
robot through a self-resetting polyfuse.

The outputs are accessed through direct connection to the XIO connector (see

Table 5-5 on

page 68

), or through the optional XIO Termination Block. See the documentation supplied

with the Termination Block for details.

XIO Output Specifications

Table 5-7. XIO Output Circuit Specifications

Parameter

Value

Power supply voltage range

See

Table 4-2 on page 54

.

Operational current range, per
channel

I

out

≤ 700 mA

Total Current Limitation, all channels
on.

I

total

≤ 1.0 A @ 50° C ambient 

I

total

≤ 1.5 A @ 25° C ambient

On state resistance (I

out

= 0.5 A)

R

on

≤ 0.32

Ω

@

85° C

Output leakage current

I

out

≤ 25 µA

Turn on response time

125 µsec max., 80 µsec typical
(hardware only)

Turn off response time

60 µsec. max., 28 µsec typical
(hardware only)

Output voltage at inductive load
turnoff (I

out

= 0.5 A, Load = 1 mH)

(+V - 65)

≤ V

demag

≤ (+V - 45)

DC short circuit current limit

0.7 A

≤ I

LIM

≤ 2.5 A

Peak short circuit current

I

ovpk

≤ 4 A