Alarm generation – EXFO FTB-8100 Series Transport Blazer for FTB-200 User Manual

Page 286

background image

SDH Tabs

274

FTB-8100 Series Transport Blazer

HOP TX (SDH)

Alarm Generation

Allows Continuous alarm generation method.

³

Type

AU-AIS (Administrative Unit - Alarm Indication Signal): Generates an
all-ones patterns over the H1, H2, H3, and SPE.

HP-RDI (High Order Path - Remote Defect Indication): Generates a
“100” pattern for bits 5, 6 and 7 of the G1 byte.

ERDI-SD (Enhanced RDI - Server Defect): Generates a “101” pattern for
the bits 5, 6 and 7 of the G1 byte.

ERDI-CD (Enhanced RDI - Connectivity Defect): Generates a “110”
pattern for the bits 5, 6 and 7 of the G1 byte.

ERDI-PD (Enhanced RDI - Payload Defect): Generates a “010” pattern
for the bits 5, 6 and 7 of the G1 byte.

H4-LOM (H4 - Loss Of Multiframe) (available with TU-11,.TU-12 and
TU-2): Generates a wrong H4 byte multiframe indicator
sequence.AU-LOP (Administrative Unit - Loss Of Pointer): Generates a
non-valid pointer.

HP-UNEQ (High Order Path - Unequipped): Generates an all-ones
pattern over POH and SPE.

³

On/Off button: The On/Off button is used to activate/deactivate the
selected alarm. This setting is disabled (Off) by default.