Alarm analysis, J0 trace – EXFO FTB-8100 Series Transport Blazer for FTB-200 User Manual

Page 185

background image

SONET Tabs

SONET/SDH Application

173

Section RX (SONET)

Alarm Analysis

³

SEF (Severely Errored Framing): A SEF defect indicates that a
minimum of four consecutive errored framing patterns are received.

³

LOF (Loss Of Frame): A Loss Of Frame alarm indicates that a Severely
Error Framing (SEF) defect on the incoming SONET signal persists for
at least 3 milliseconds.

³

TIM-S (Trace Identifier Mismatch - Section): The TIM-S defect indicates
that the received J0 Trace doesn’t match the expected message value.
The TIM-S alarm is only available when Enable TIM-S check box from
J0 Trace section has been selected.

J0 Trace

³

Received Message: Displays the received J0 value. The
represents the CRC-7 for a 16-bytes format. The last two bytes of a
64-bytes format,

R

> and

F

>, represent respectively a carriage

return and a line feed.

³

Enable TIM-S (Trace Identifier Mismatch - Section): Allows enabling
the Trace Identifier Mismatch for the expected message defined.
Enable TIM-S has to be enabled to give access to the expected trace
format and message.

³

Expected Message: Allows entering the expected J0 Trace message. J0
value should be ASCII suitable characters. The default message is
EXFO SONET/SDH for 16 bytes and EXFO SONET/SDH Analyzer
Section/RS trace test message
for 64 bytes.

³

Expected Format: Allows the selection of the expected format: 16 or
64 bytes. The default setting is 16 bytes.