SONET Tabs

174

FTB-8100 Series Transport Blazer

Section OH TX/RX (SONET)

Section OH TX/RX (SONET)

The Section OH TX allows changing the transport overhead information to
be transmitted while the Section OH RX allows verification of the transport
overhead information received. Refer to Glossary on page 413 for detailed
overhead information.

Press Main, Test, SONET, Section, and OH TX/RX.

Section Overhead

³

Timeslot: Select the timeslot number that will be used for verification.
Choices are 1 to 3, 12, 48, or 192 depending on the OC-N interface
selected. The default setting is 1.

³

Binary: Allows either displaying all overhead values in binary (when
the Binary check box is selected) or hexadecimal (when the Binary
check box is cleared). This Binary check box is cleared by default.

³

A1 and A2: Framing. The value should be hexadecimal F6 for A1 and
28 for A2.