OTN Tabs
SONET/SDH Application
155
ODU TTI/FTFL TX
FTFL TX
Allows the configuration of the Forward and Backward ODU Fault Type
Fault Location (FTFL) to be generated.
³
Fault Indication and Fault Indication Code allows the selection of the
FTFL fault indicator message/code (byte 0 for forward, byte 128 for
backward) to be generated. The default setting is No fault (00).
Choices are:
Note: The Fault Indication Code field is automatically updated when the Fault
Indication is changed and vice versa.
Binary allows either displaying the Fault Indication Code in binary
(when enabled) or hexadecimal (when disabled). This setting is
disabled by default.
³
Operator Identifier allows editing the Operator Identifier (bytes 1 to 9
for forward, byte 129 to 137 for backward) to be generated. A
maximum of 9 characters are allowed. By default no Operator
Identifier is defined.
³
Operator Specific allows editing the Operator Specific (bytes 10 to 127
for forward, byte 138 to 255 for backward) to be generated. A
maximum of 118 characters are allowed. By default no Operator
Specific is defined.
Fault Indication
Fault Indication Code
No fault
00
Signal fail
01
Signal Degrade
02
Reserved
03
a
a.
Selecting Reserved will use the hexadecimal code 03 but, all codes from 03 to FF
are reserved for future international standardization.