beautypg.com

Lop oh tx/rx (sonet), Path overhead – EXFO FTB-8100 Series Transport Blazer for FTB-200 User Manual

Page 222

background image

SONET Tabs

210

FTB-8100 Series Transport Blazer

LOP OH TX/RX (SONET)

LOP OH TX/RX (SONET)

The LOP OH TX allows changing the low order path overhead information
to be transmitted while the LOP OH RX allows verification of the low order
path overhead information received.

Press Main, Test, SONET, LOP, and OH TX/RX.

Path Overhead

³

Binary allows either displaying all overhead values in binary (when
enabled) or hexadecimal (when disabled). This setting is disabled by
default.

³

V5 (VT Path Overhead)

³

J2 (VT Path Trace). J2 is only available when Enable Trace from the
LOP TX (SONET) on page 203 is disabled.

³

Z6: VT Tandem Connection Monitoring

³

Z7: Extended signal label