Alarm analysis, J0 trace – EXFO FTB-8100 Series Transport Blazer for FTB-200 User Manual
Page 268

SDH Tabs
256
FTB-8100 Series Transport Blazer
Regenerator Section RX (SDH)
Alarm Analysis
³
OOF (Out Of Frame): A OOF alarm indicates that a minimum of four
consecutive errored framing patterns are received.
³
LOF (Loss Of Frame): A LOF alarm indicates that an Out Of Frame
(OOF) defect on the incoming optical signal persists for 3 milliseconds.
³
RS-TIM (Regenerator Section - Trace Identifier Mismatch): The RS-TIM
defect indicates that the received J0 Trace doesn’t match the expected
message value. RS-TIM alarm is only available when the Enable
RS-TIM check box is selected.
Note: Refer to Alarm/Error Measurements on page 44 for H/C LEDs, and Seconds
information.
J0 Trace
³
Received Message: Displays the J0 value in 16 or 64 bytes format. The R > and F >, represent respectively a carriage return and a line feed. ³ Enable RS-TIM (Regenerator Section - Trace Identifier Mismatch): ³ Expected Message: Allows entering the message that is expected. ³ Expected Format: Allows the selection of the format expected.
of a 64-bytes format,
Enables the Trace Identifier Mismatch for the expected message
defined when the Enable RS-TIM check box is selected. The Enable
RS-TIM check box has to be selected to give access to the expected
trace format and message. When the Enable RS-TIM check box is
selected, the J0 1-byte is available from the Regenerator Section OH
TX/RX (SDH) on page 257.
J0 value should be ASCII suitable characters. The default message is
EXFO SONET/SDH for 16 bytes and EXFO SONET/SDH Analyzer
Section/RS trace test message for 64 bytes.
Choices are 16 or 64 bytes. The default setting is 16 bytes.