Chapter 5 Installation

5

5.1.3 Mounting the BL-600/601/600HA/601HA

The following is the procedure for mounting the BL-600/601/600HA/601HA with the
supplied mounting bracket. To mount the BL-600 Series without the mounting
bracket, refer to “Mounting the BL-600 Series without the mounting bracket” on
pages 79 and 80.

1. Check the surroundings of the mounting position.

Check the surroundings according to “Situations to check for before installing
the BL-600 Series” on pages 72 and 73.

2. Attach the BL-600 Series to the mounting bracket.

➮ Refer to page 155 for the dimensions of the mounting bracket.

When bracket A is used

When bracket B is used

3. Temporarily fix the mounting bracket.

The angle of the laser beam application is 15

° when the BL-600 Series is

secured to the mounting bracket as shown below.

➮ See “5.1.2 Mounting angle and distance” on page 74 for the mounting distance.

When mounting bracket A is used:

When mounting bracket B is used:

Supplied mounting
screw (M3)

Laser beam

Mounting bracket A

Laser beam

Mounting bracket B

Supplied mounting
screw (M3)

BL-600 Series

Perpendicular
line

Bar code

Mounting bracket

15

°

BL-600 Series

Perpendicular
line

Bar code

Mounting bracket

15

°

Bar code

Mounting
bracket

Bar code

Mounting
bracket