KEYENCE BL-600 Series User Manual

Page 55

background image

45

Chapter 4 Setup Software

4

4.2.3 [[Comm Settings-1]] (Communication parameters 1) screen

Set the following items.

“Baud rate”

“Data bits”

“Stop bits”

“Parity”

Set these communication parameters according to the settings of the exter-
nal devices that will be connected (PC, PLC, etc.).

“Multi-drop link (RS-485)”

➮ See “Multi-drop controller N-400 User’s Manual”.

1. Select “Enable” to use multi-drop link.

*

If the multi-drop link is enabled, “RTS/CTS” is disabled.

2. The “ID number (1-31)” setup box appears. Specify the ID number as a

value between 1 to 31. Be sure not to set the same number for different
BL-600 units in the same multi-drop link.

“RTS/CTS”

➮ See page 112.

Select “RTS/CTS” to suspend read data transmission with the CTS signal of
RS-232C.

“Baud rate”

“Stop bits”

“RTS/CTS”

“Parity”

“Data bits”

“Multi-drop link
(RS-485)”

“RTS/CTS”
Cannot be selected.

“ID number (1-31)”