The 24dB Pad and +48V Phantom Power will require confirmation via a dialog box in Pro64 Network
Manager. Click
Y
es
to apply the change or
N
o
to cancel.
Confirmation is required for changes to +48V and Pad settings.
Any updates to mic preamp channel strip settings made from other controllers in the network (such as an
RCI/MCS combination or a Yamaha device with a Pro64 A‑Net card installed) will automatically update the
on‑screen settings.
Clearing Channel Settings
Two convenient functions are found in the Channel Settings menu that can simplify the editing of 6416m
mic preamp parameters. Use the
c
leAr
c
hANNel
s
ettINgs
command on a selected channel to reset a single
preamp channel to the defaults. Or use the
c
leAr
A
ll
c
hANNel
s
ettINgs
command to reset all 16 preamp
channel strips at once. It is not necessary to select channels first when using this command.
Both Clear Channels settings commands require confirmation. Save a Device Preset before clearing the
channel settings if you need to recall the current preamp settings at a later time.
Outputs From Network View
The AllFrame, 6416o, 6416Y2, and 6416dio each contain an Outputs from Network view that shows details
about the active network Slots assigned to their outputs. The ASI A‑Net System Interface also has an
Outputs from Network view, but offers features designed to simplify routing Pro64 Slots to Pro16 devices
such as A‑16II Personal Mixers. See page 108.
As with an input device, the
c
h
column is related to the physical output channels available from the Pro64
device and is a read‑only field. An AllFrame device shows the I/O card’s installed location as well as the
channel number on that card (displayed as A1‑A4, B1‑B4, etc.).
The
A
ctIve
column has yellow indicators that work as on/off switches for the audio assigned to the device’s
channels. Click any switch to toggle its state (see the exceptions starting on page 110 for the 6416Y2 card
and ASI). Since the outputs from a Pro64 device do not alter the makeup of the Pro64 network’s inputs, no
confirmation dialogs are required; output channel status can be changed at any time.