Chps-series stage dimensions, Figure 21 - chps-a6xxxa-xlmxxx – Rockwell Automation CHPS-250 Linear Stage Installation User Manual
Page 77
Rockwell Automation Publication CHPS-UM001D-EN-P - July 2014
77
Specifications and Dimensions Appendix A
CHPS-Series Stage
Dimensions
Stage are designed to metric dimensions. Inch dimensions are conversions from
millimeters. Dimensions without tolerances are for reference.
Figure 21 - CHPS-A6xxxA-xLMxxx
(4X) M6 x 1.0-6H 12.0 (0.47)
25.0
(0.98)
25.0
(0.98)
165
(6.50)
30
(1.18)
Slide
239
(9.41)
167
(6.57)
62
(2.44)
(4X)
Ø 7.0 (0.28) Thru
Pilot Hole
45.0 (1.80)
115
(4.53)
30.0
(1.18)
123.8
(4.88)
46.8
(1.84)
181.5
(7.15)
238.6
(9.39)
8.5
(0.33)
32.0
(1.26)
92.0
(3.62)
150
(5.9)
7.6
(0.30)
Travel
165
(6.50)
30.5 (1.20)
Mechanical
Overtravel
30.5 (1.20)
Mechanical
Overtravel
120 (4.72)
Toe Clamp/T-Nut Spacing
350.0
(13.87)
Bracket located ±51 (2.0)
from center of travel.
See Detail A
(4X) M10 x 1.5-6H Thru (2 per end cap)
Access point for lubricating linear bearings.
Provision to use lifting hooks (not provided).
Detail A
9.3 (0.37)
Depth, max
Toe Clamp is standard for
covered stages. Mount to base
using M6 x1.0 socket cap screw.
T-Nut Mount to base using
M6 x1.0 hardware
(optional accessory).
Ground Screw
M5 x 0.8-6H
+ Travel
Travel
Length mm (in.)
Shortest 60
(2.36)
Increments
60 (2.36)
Longest 1620
(63.78)