Lubricate the bearing, Optical encoder scale maintenance – Rockwell Automation CHPS-250 Linear Stage Installation User Manual
Page 60
60
Rockwell Automation Publication CHPS-UM001D-EN-P - July 2014
Chapter 9
Maintenance
Lubricate the Bearing
Your stage requires lubrication every 6 months or 2500 km (1550 mi) of travel,
which ever comes first. Use the MPAS grease gun kit and grease cartridge, catalog
numbers MPAS-GPUMP and MPAS-CART respectively.
1. Position slide at end of travel and clamp it to hold the stage against end
cap.
2. Remove the lubrication port protective caps.
3. Insert the tip of grease gun in the lubrication port. Push in until contact
with bearing grease nipple is felt.
4. Pump handle until back pressure is felt or two strokes are completed.
5. Repeat steps 3 and 4 to the second bearing on this side.
6. Move slide to opposite end of travel and repeat steps 1
…
5.
7. Remove clamp.
8. Reinstall the protective caps on all the lubrication ports.
Optical Encoder Scale
Maintenance
1. If installed remove strip seal and side cover on the side opposite the cable
carrier.
2. Clear any coarse or abrasive particles with a clean air line with maximum
pressure of 10 psi.
3. Clean scale with a clean dry cloth. Avoid the use of solvents.
4. If necessary use isopropyl alcohol sparingly, apply with a wetted cloth by
using a gentle wiping action.
5. Reinstall side cover and strip seal, if used.
ATTENTION: Do not use clamp across the side panels. This can deform
and damage the side panels.
Bearing Lubrication Ports (2x per end cap)