Encoder specifications, Maximum velocity for allen-bradley drives – Rockwell Automation CHPS-250 Linear Stage Installation User Manual
Page 74
![background image](/manuals/580967/74/background.png)
74
Rockwell Automation Publication CHPS-UM001D-EN-P - July 2014
Appendix A Specifications and Dimensions
Encoder Specifications
Maximum Velocity for Allen-Bradley Drives
Table 10 - Maximum Velocity for 150 mm frame size CHPS-Series Linear Stages with Allen-Bradley
Drives
Table 11 - Maximum Velocity for 200 and 250 mm frame size CHPS-Series Linear Stages with
Allen-Bradley Drives
Type
Signal
Specification
Power Supply
5V DC ±5%
Digital
A/B/Index
RS422 Differential Line Driver
Analog
Sine/Cosine
0.6…1.2V p-p Differential Analog
Integral Index Mark
Differential Pulse 0.8…1.3V p-p
IMPORTANT
Contact Application Engineering for third party drives and controllers. The controls
need to meet a minimum recommended counter clock frequency that varies with
encoder type and resolution and required peak speed.
Incremental Encoder Option
Maximum Velocity
Digital
Resolution
Sine/Cosine
Period
Velocity,
max
Ultra™ 3000 and
Ultra5000 Drives
Kinetix 2000 and
Kinetix 6500 Drives
Kinetix 6000
Drive
Kinetix 300
Drive
μm/count
μm
m/s
m/s
m/s
m/s
m/s
1
—
5.0
4.0
4.0
1.5
2.0
0.5
—
3.0
2.0
2.0
0.7
—
0.1
—
0.7
0.5
—
—
—
—
20
4.0
2.0
2.0
2.0
—
Incremental Encoder Option
Maximum Velocity
Digital
Resolution
Sine/Cosine
Period
Velocity,
max
Ulta3000 and
Ultra5000 Drives
Kinetix 2000 and
Kinetix 6500 Drives
Kinetix 6000
Drive
Kinetix 300
Drive
μm/count
μm
m/s
m/s
m/s
m/s
m/s
1
—
5.0
4.0
4.0
1.5
2.0
0.5
—
3.0
2.0
2.0
0.7
—
0.1
—
0.7
0.5
0.5
(1)
—
—
—
20
4.0
2.0
2.0
2.0
—
(1) LC motor option only.