beautypg.com

Encoder specifications, Maximum velocity for allen-bradley drives – Rockwell Automation CHPS-250 Linear Stage Installation User Manual

Page 74

background image

74

Rockwell Automation Publication CHPS-UM001D-EN-P - July 2014

Appendix A Specifications and Dimensions

Encoder Specifications

Maximum Velocity for Allen-Bradley Drives

Table 10 - Maximum Velocity for 150 mm frame size CHPS-Series Linear Stages with Allen-Bradley
Drives

Table 11 - Maximum Velocity for 200 and 250 mm frame size CHPS-Series Linear Stages with
Allen-Bradley Drives

Type

Signal

Specification

Power Supply

5V DC ±5%

Digital

A/B/Index

RS422 Differential Line Driver

Analog

Sine/Cosine

0.6…1.2V p-p Differential Analog

Integral Index Mark

Differential Pulse 0.8…1.3V p-p

IMPORTANT

Contact Application Engineering for third party drives and controllers. The controls
need to meet a minimum recommended counter clock frequency that varies with
encoder type and resolution and required peak speed.

Incremental Encoder Option

Maximum Velocity

Digital
Resolution

Sine/Cosine
Period

Velocity,
max

Ultra™ 3000 and
Ultra5000 Drives

Kinetix 2000 and
Kinetix 6500 Drives

Kinetix 6000
Drive

Kinetix 300
Drive

μm/count

μm

m/s

m/s

m/s

m/s

m/s

1

5.0

4.0

4.0

1.5

2.0

0.5

3.0

2.0

2.0

0.7

0.1

0.7

0.5

20

4.0

2.0

2.0

2.0

Incremental Encoder Option

Maximum Velocity

Digital
Resolution

Sine/Cosine
Period

Velocity,
max

Ulta3000 and
Ultra5000 Drives

Kinetix 2000 and
Kinetix 6500 Drives

Kinetix 6000
Drive

Kinetix 300
Drive

μm/count

μm

m/s

m/s

m/s

m/s

m/s

1

5.0

4.0

4.0

1.5

2.0

0.5

3.0

2.0

2.0

0.7

0.1

0.7

0.5

0.5

(1)

20

4.0

2.0

2.0

2.0

(1) LC motor option only.

This manual is related to the following products: