beautypg.com

Performance specifications for 325v or, 650v chps-series stage – Rockwell Automation CHPS-250 Linear Stage Installation User Manual

Page 71

background image

Rockwell Automation Publication CHPS-UM001D-EN-P - July 2014

71

Specifications and Dimensions Appendix A

Table 7 - Performance Specifications for 150 mm frame size CHPS-Series Linear Stages

Table 8 - Performance Specifications for 200 mm frame size CHPS-Series Linear Stages

Performance Specifications for 250 mm frame size CHPS-Series Linear Stages

Performance Specifications for 325V or 650V CHPS-Series Stage

Maximum cable length 10 m (33 ft). Please contact Applications Engineering
concerning application requiring longer cables.

Cat. No.

Slide Mass

Continuous

(1)

(2)

Peak Maximum

Static Load

(3)

Max Static Moment Loads

(3)

Current Thrust

Current

Thrust

Pitch

Yaw

Roll

kg (lb)

A rms (Ao-pk)

N (lbf)

A rms (Ao-pk)

N (lbf)

kN (lbf)

kN (lbf)

N•m (ft•lb)

N•m (ft•lb)

CHPS-A6xxxA-xLMxxx

4.64 (10.23)

2.3 (3.3)

80 (18)

7.0 (9.9)

239 (54)

38.0 (8722)

71 (52)

183 (134)

97 (71)

CHPS-A6xxxB-xLMxxx

6.48 (14.28)

4.7 (6.6)

160 (36)

14.0 (19.9)

479 (108)

38.0 (8722)

128 (94)

327 (241)

97 (71)

CHPS-A6xxxC-xLMxxx

6.48 (14.28)

2.3 (3.3)

160 (36)

7.0 (9.9)

479 (108)

38.0 (8722)

128 (94)

327 (241)

97 (71)

(1) Measured at 20 °C (68 °F) ambient.
(2) For covered and sealed stages derate by 10%
(3) Values apply to bearing rating only. Contact Applications Engineering for structural considerations.

Cat. No.

Slide Mass

Continuous

(1)

(2)

Peak Maximum

Static Load

(3)

Max Static Moment Loads

(3)

Current Thrust

Current

Thrust Pitch

Yaw

Roll

kg (lb)

A rms (Ao-pk)

N (lbf)

A rms (Ao-pk)

N (lbf)

kN (lb)

kN (lbf)

N•m (ft•lb)

N•m (ft•lb)

CHPS-A8xxxA-xLMxxx

4.59 (10.1)

2.1 (3.0)

72 (16)

6.3 (8.9)

215 (48)

66 (14836)

171 9126)

412 (304)

270 (199)

CHPS-A8xxxB-xLMxxx

6.58 (14.5)

4.2 (6.0)

144 (32)

12.6 (17.9)

431 (97)

66 (14836)

270 (199)

620 (457)

270 (199)

CHPS-A8xxxC-xLMxxx

6.58 (14.5)

2.1 (3.0)

144 (32)

6.3 (8.9)

431 (97)

66 (14836)

270 (199)

620 (457)

270 (199)

(1) Measured at 20 °C (68 °F) ambient.
(2) For covered and sealed stages derate by 10%.
(3) Values apply to bearing rating only, Contact Applications Engineering for structural considerations.

Cat. No.

Slide Mass

Continuous

(1)(2)

Peak Maximum

Static Load

(3)

Max Static Moment Loads

(3)

Current Thrust

Current

Thrust

Pitch

Yaw

Roll

kg (lb)

A rms (Ao-pk)

N (lbf)

A rms (Ao-pk)

N (lbf)

kN (lbf)

kN (lbf)

N•m (ft•lb)

N•m (ft•lb)

CHPS-A9xxxG-xLMxxx

8.58 (18.9)

1.9 (2.7)

109 (25)

5.8 (8.2)

328 (74)

93.6 (21042)

170 (125)

385 (283)

508 (375)

CHPS-A9xxxH-xLMxxx

9.62 (21.2)

3.8 (5.4)

219 (49)

11.5 (16.3)

656 (147)

93.6 (21042)

324 (239)

734 (541)

508 (375)

CHPS-A9xxxI-xLMxxx

9.62 (21.2)

1.9 (2.7)

219 (49)

5.8 (8.2)

656 (147)

93.6 (21042)

324 (541)

734 (541)

508 (375)

(1) Measured at 20 °C (68 °F) ambient.
(2) For covered and sealed stages derate by 10%.
(3) Values apply to bearing rating only. Contact Applications Engineering for structural considerations.

This manual is related to the following products: