Mount your kinetix 300 drive – Rockwell Automation 2097-Vxxx Kinetix 300 EtherNet/IP Indexing Servo Drive User Manual User Manual
Page 34
34
Rockwell Automation Publication 2097-UM001D-EN-P - November 2012
Chapter 2
Installing the Kinetix 300 Drive System
Mount Your Kinetix 300 Drive
This procedure assumes you have prepared your panel and understand how to
bond your system. For installation instructions regarding other equipment and
accessories, see the instructions that came with those products.
Follow these steps to mount your Kinetix 300 drive.
1. Lay out the position for the Kinetix 300 drive and accessories in the
enclosure.
for panel layout
recommendations. Mounting hole dimensions for the Kinetix 300 drive
are shown in Kinetix Servo Drives Specifications Technical Data,
publicatio
2. Attach the Kinetix 300 drive to the cabinet, first by using the upper
mounting slots of the drive and then the lower.
The recommended mounting hardware is M4 (#6-32) steel machine
screws torqued to 1.1 N•m (9.8 lb•in). Observe bonding techniques as
described in
.
3. Tighten all mounting fasteners.
ATTENTION: This drive contains electrostatic discharge (ESD) sensitive parts
and assemblies. You are required to follow static control precautions when you
install, test, service, or repair this assembly. If you do not follow ESD control
procedures, components can be damaged. If you are not familiar with static
control procedures, see Allen-Bradley publication
, Guarding Against
Electrostatic Damage or any other applicable ESD Protection Handbook.
IMPORTANT
To improve the bond between the Kinetix 300 drive and subpanel,
construct your subpanel out of zinc plated (paint-free) steel.