beautypg.com

Configure the kinetix 300 drive – Rockwell Automation 2097-Vxxx Kinetix 300 EtherNet/IP Indexing Servo Drive User Manual User Manual

Page 136

background image

136

Rockwell Automation Publication 2097-UM001D-EN-P - November 2012

Chapter 6

Configure and Start Up the Kinetix 300 Drive

4. Configure the new module.

a. Name the module.
b. Enter the IP address of the Ethernet module.

In this example, the IP address is 192.168.124.2. This is the controller
Ethernet address, not the drive Ethernet address.

c. Enter the slot where your module resides (leftmost slot = 0).

5. Click OK.

Configure the Kinetix 300 Drive

Follow these steps to configure the Kinetix 300 drive.

1. Right-click the embedded

1769-L23E Ethernet port
and choose New Module.

The Select Module dialog box opens.

2. Expand the Drives category and select your Bulletin 2097 drive as

appropriate for your actual hardware configuration.

In this example, the 2097-V33PR3 drive is selected.

3. Click OK.