System Signal Variables Appendix B

Cnt[0x].Time Overflow

(1)

Read

Overflow indication for the time stamp of the counters

True

24-bit overflow since last measurement

False

No 24-bit overflow since last measurement

Cnt[0x].Direction

(1)

Read/Write

Counting direction of the counter
(only if Cnt[0x].Auto Advance Sense = False)

True

upward (increment)

False

downward (decrement)

Cnt[0x].Auto Advance
Sense

(1)

Read/Write

Automatic counter direction recognition

True

Automatic recognition on

False

Manual setting of counter direction

Cnt[0x].Reset

(1)

Read/Write

Reset counter

True

No reset

False

Reset

Cnt[0x].5/24V Mode

(1)

Read/Write

Counter input 5V or 24V

True

24V

False

5V

Cnt[0x].Gray Code

(1)

Read/Write

Decoder or pulse operation

True

Gray Code decoder

False

Pulse operation

(1) Ox = counter 01 or 02.

I/O Data

Read/Write

Description