Specifications and supplementals information, Chapter objectives, Specifications – Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual
Page 253: Chapter, Chapter objectives specifications

Chapter
10
Publication 1336 FORCE–5.13 –– September, 1998
Specifications and
Supplementals Information
Chapter 10 provides specifications and supplemental information
including a parameter cross reference by number or name, parameter
block diagrams, a hardware block diagram, and PLC
Communications Adapter Board DIP switch settings.
The following table shows the specifications for the PLC
Communications Adapter Board:
This category:
Has these specifications:
Environmental
Operating temperature: 0 to 40
°
C (32 to 104
°
F)
Storage temperature: –40 to 70
°
C (–40 to 158
°
F)
Relative humidity: 5 to 95% non–condensing
Shock: 15G peak for 11 ms duration (
±
1.0 ms)
Vibration: 0.15 mm (0.006 inches) displacement, 1G peak
Electrical
Input voltage: supplied by drive
Input frequency: NA
Input current: NA
SCANport load: 60 mA
Vibration: 0.15 mm (0.006 inches) displacement, 1G peak
Communications
Drive side: SCANport peripheral interface
PLC side: Allen–Bradley RIO/DH+
Baud rate: 57.6K, 115.2K, or 230.4K
Rack size: 1/4, 1/2, 3/4, or full
Product
Compatibility
The PLC Communications Adapter Board is designed to be
used with the following terminal interface devices (TIDs):
Drive Tools
Allen–Bradley Programmable Controllers
➀
•
PLC–5/10, PLC–5/15, PLC–5/25 Family
•
PLC–5/40 and 5/60 as scanner and as adapter
➁
•
PLC –5/40L Family
1771–ASB
➁
Flex I/O
➁
➀
These adapters were tested with the current revision level
of the listed PLC processors. Earlier versions of these
processors may not be compatible.
➁
RIO scanner has only been tested with these devices.
Chapter Objectives
Specifications