Fault queue, Plc block transfer instruction data, Fault entry read full – Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual
Page 167
![background image](/manuals/578856/167/background.png)
7–21
Publication 1336 FORCE–5.13 –– September, 1998
The Fault Entry Read Full function reads the contents of the fault
queue entry number specified. A message is returned that includes
the fault text and fault code associated with the specified fault queue
entry and the time stamp associated with the fault.
PLC Block Transfer Instruction Data
BTW instruction length:
3 words
BTR instruction length:
12 or 16 words
Message
3
Header
Word 1
Header
Word 1
PLC Decimal Value
1792
Header
Word 2
Fault Queue Entry
Number
Header
Word 3
PLC Decimal Value
1792 –– Message OK
Header
Word 2
Data
Word 3
-30976 –– Message Error
Data
Word 4
Data
Word 5
Fault Text
Character 2
Character 1
Fault Text
Character 4
Character 3
Fault Queue Entry
Number
Data
Word 6
Fault Text
Character 6
Character 5
Data
Word 7
Fault Text
Character 8
Character 7
Data
Word 8
Fault Text
Character 10
Character 9
Data
Word 9
Fault Text
Character 12
Character 11
Data
Word 10
Fault Text
Character 14
Character 13
Data
Word 11
Fault Text
Character 16
Character 15
Message Structure
0
PLC Request –– Block Transfer Write
Data
Word 12
Fault Code Value
Data
Word 13
Clock Time
Seconds
Ref
Data
Word 14
Clock Time
Hour
Minute
Data
Word 15
Clock Time
Date
Day
Data
Word 16
Clock Time
Year
Month
Drive Response –– Block Transfer Read
Fault Queue
Fault Entry Read Full