beautypg.com

Link read, Plc block transfer instruction data, Message operation – Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual

Page 178: Scattered parameter link read

background image

7–32

Publication 1336 FORCE–5.13 –– September, 1998

The Scattered Parameter Link Read message returns a list of up to 30
links in the source-to-sink order found in the drive. The links do not
have to be in consecutive order.

PLC Block Transfer Instruction Data

BTW instruction length:

5-63 words

BTR instruction length:

5-63 words

Message Length

5-63

Header

Word 1

PLC Decimal Value

5

Header

Word 2

Data

Word 3

PLC Decimal Value

5 –– Message OK

-32763 –– Message Error

Data

Word 4

Number of Parameter

Links to Read

Parameter Number

1

Number of Parameter

Links to Read

Parameter

Number 1

Data

Word 6

Parameter Number

2

Data

Word 62

Parameter Number

30

Bit 15

Parameter

Number 2

Bit 15

Data

Word 63

Parameter

Number 30

Bit 15

Data

Word 7

Data

Word 5

Data

Word 63

Message Structure

0

0

0

Data

Word 7

Data

Word 6

Data

Word 5

Data

Word 4

Data

Word 3

Header

Word 2

Header

Word 1

0

Data

Word 62

Source Parameter

Number 1

Source Parameter

Number 2

Source Parameter

Number 30

PLC Request –– Block Transfer Write

Drive Response –– Block Transfer Read

Message Operation

The Scattered Parameter Link Read function requested in the BTW
reads up to 30 non-consecutive links made in the drive. You request
the desired link information by defining the sink parameters in the
BTW message.

Link Read

Scattered Parameter Link Read