beautypg.com

Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual

Page 143

background image

6–53

Publication 1336 FORCE–5.13 –– September, 1998

481

Trend 3 Select

[Tr3 Select]

Tr3 Select specifies the trend mode. The states are
as follows:

0

Disable the trend.

1

Enable the trend.

2

Force a true trigger condition.

Parameter Number

481

Parameter Type

Read/Write, Non–Linkable Sink

Display Units / Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

2

File – Group

Diagnostics – Trend Setup

Enums

0 = Disable

1 = Enable

2 = Force Trig

482

Trend 3 Status

[Tr3 Status]

Tr3 Status identifies which state the trend is
currently in. The following states are possible:

1 Stopped

Trending is not executing.

2 Running

Trending is executing, but the trigger
point has not yet been reached.

3 Tripped/Trigger Trending is executing, and the trigger

point has been reached.

4 Tripped/Forced The trigger point was forced.

Parameter Number

482

Parameter Type

Read Only, Non–Linkable Source

Display Units / Drive Units

None

Factory Default

1

Minimum Value

1

Maximum Value

4

File – Group

Diagnostics – Trend I/O

Enums

1 = Stopped

2 = Running

3 = Trip Trig

4 = Force Trip

483

Trend Output 3

[Trend Out 3]

Trend Out 3 displays the latest 500 trend input data
values once the trigger condition is true and all post
samples are gathered. This parameter is updated at
the same rate as the data was sampled. This
parameter can be linked to Analog Output (for
example) and a chart recorder connected to Analog
Output to provide a hard copy of the trend data.

Parameter Number

483

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

+32767

File – Group

Diagnostics – Trend I/O

484

Trend Input 4

[Trend In 4]

Trend In 4 specifies the data value to sample at the
specified trend sample rate. You should link Trend
In 4 to a source parameter (such as velocity, torque,
or current) for the trend to make sense.

Parameter Number

484

Parameter Type

Read/Write, Sink

Display Units / Drive Units

Dependent on Link➀

Factory Default

0

Minimum Value

–32767➀

Maximum Value

+32767➀

File – Group

Diagnostics – Trend I/O

➀ These values depend on the source parameter that this parameter is linked to.
For example, if the source parameter’s drive units are rpm, then Trend In 4’s drive
units will be displayed in rpm. The minimum and maximum values are also link
dependent.