Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual
Page 121

6–31
Publication 1336 FORCE–5.13 –– September, 1998
391
SCANport Analog Select
[SP Analog Sel]
SP Analog Sel indicates which port (1 through 5) is
to receive the SCANport analog input value that
appears in parameter 338, SP Analog In.
Parameter Number
391
Parameter Type
Read/Write, Sink
Display Units / Drive Units
None
Factory Default
1
Minimum Value
1
Maximum Value
5
File – Group
Communications I/O – Analog Output
Enums
1 = Port 1
2 = Port 2
3 = Port 3
4 = Port 4
5 = Port 5
392
Analog Input 1 Offset
[Analog In 1 Offset]
Analog In 1 Offset determines the offset applied to
the raw Analog In 1 values before the scale factor is
applied. This allows you to shift the range of the
analog input.
Parameter Number
392
Parameter Type
Read/Write, Non–Linkable Sink
Display Units / Drive Units
±
4096
Factory Default
0
Minimum Value
–20 Volts
Maximum Value
+20 Volts
File – Group
Communications I/O – Analog Input
393
Analog Input 1 Scale
[Analog In 1 Scale]
Analog In 1 Scale determines the scale factor or
gain for the Analog In 1 value. A +10V dc signal
applied to Analog In 1 at TB21 is converted to a
+2048 digital value used by the 1336 FORCE.
Before the digital value is displayed or transferred to
the drive, the scale factor is applied allowing an
effective digital range of
±
32767 (16 x 2048). The
absolute digital value is clamped at 32767.
Scale Factor
Drive Units
1
2048
2
4096
4
8192
16
32767
Parameter Number
393
Parameter Type
Read/Write, Non–Linkable Sink
Display Units / Drive Units
±
32767
Factory Default
+1
Minimum Value
–16
Maximum Value
+16
File – Group
Communications I/O – Analog Input
394
Analog Input 2 Offset
[Analog In 2 Offset]
Analog In 2 Offset determines the offset applied to
the raw Analog In 2 values before the scale factor is
applied. This allows you to shift the range of the
analog input.
Parameter Number
394
Parameter Type
Read/Write, Non–Linkable Sink
Display Units / Drive Units
±
4096
Factory Default
0
Minimum Value
–20 Volts
Maximum Value
+20 Volts
File – Group
Communications I/O – Analog Input