7 reset error, 8 delete logbook, Reset error – Lenze 8400 BaseLine D User Manual
Page 52: Delete logbook, 4device control (dctrl)

4
Device control (DCTRL)
4.1
Device commands
52
Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.1.7
Reset error
The
= "1: On / start" device command acknowledges an existing error message if the error
cause has been eliminated and thus the error is not pending anymore.
• After resetting the current error, further errors may be pending which must be reset as well.
• The last 8 errors are displayed in
.
Tip!
An error message can also be acknowledged by activating the Reset error button in the
Diagnostics tab.
In the Lenze setting, switching RFR also causes an error acknowledgement (see configura-
tion parameter
Detailed information on error messages can be found in the chapter entitled "
4.1.8
Delete logbook
The
= "1: On / start" device command deletes all logbook entries.
Tip!
Click the Logbook button in the Diagnostics tab to display the logbook in the »Engineer«.
In the Logbook dialog box, it is also possible to delete all logbook entries by clicking the
Delete button.
Detailed information on the logbook can be found in the chapter entitled "