9parameter reference, 3 table of attributes 222 – Lenze 8400 BaseLine D User Manual
Page 222

9
Parameter reference
9.3
Table of attributes
222
Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
DCB: Current
24539
5FDB
E
1
INTEGER_16
100
Fixed setpoint x (L_NSet_1 n-Fix)
24536
5FD8
A
3
INTEGER_16
100
MCTRL: Speed setpoint
24525
5FCD
E
1
INTEGER_32
1
MCTRL: Actual speed value
24524
5FCC
E
1
INTEGER_32
1
Motor voltage
24523
5FCB
E
1
UNSIGNED_16
1
DC-bus voltage
24522
5FCA
E
1
UNSIGNED_16
1
Motor current
24521
5FC9
E
1
UNSIGNED_16
100
Torque
24519
5FC7
A
2
INTEGER_32
100
Maximum torque
24518
5FC6
E
1
UNSIGNED_32
100
Output frequency
24517
5FC5
E
1
INTEGER_32
100
Appl.: Reference frequency C11
24516
5FC4
E
1
UNSIGNED_32
100
Heatsink temperature
24514
5FC2
E
1
INTEGER_16
1
Device utilisation (Ixt)
24511
5FBF
A
3
INTEGER_16
100
Thermal motor load (I²xt)
24509
5FBD
E
1
INTEGER_16
100
Vp Imax controller
24502
5FB6
E
1
UNSIGNED_16
100
Ti Imax controller
24501
5FB5
E
1
UNSIGNED_16
1
Rated motor power
24494
5FAE
E
1
UNSIGNED_16
100
Motor stator resistance
24491
5FAB
E
1
UNSIGNED_32
1
Motor stator leakage inductance
24490
5FAA
E
1
UNSIGNED_16
100
Rated motor speed
24488
5FA8
E
1
UNSIGNED_16
1
Rated motor current
24487
5FA7
E
1
UNSIGNED_16
100
Rated motor frequency
24486
5FA6
E
1
UNSIGNED_16
1
Rated motor voltage
24485
5FA5
E
1
UNSIGNED_16
1
Motor cosine phi
24484
5FA4
E
1
UNSIGNED_8
100
Motor magnetising inductance
24483
5FA3
E
1
UNSIGNED_16
10
Power section identification
24482
5FA2
E
1
UNSIGNED_16
1
Password
24481
5FA1
E
1
INTEGER_32
1
Motor magnetising current
24480
5FA0
E
1
UNSIGNED_16
100
Rated motor torque
24478
5F9E
E
1
UNSIGNED_32
100
Rated device current
24477
5F9D
E
1
UNSIGNED_16
10
Firmware version
24476
5F9C
E
1
VISIBLE_STRING
Firmware version
24475
5F9B
A
4
UNSIGNED_8
1
Deceleration time - quick stop
24470
5F96
E
1
UNSIGNED_32
1000
Auto-DCB: Hold time
24469
5F95
E
1
UNSIGNED_32
1000
DCB: Hold time
24468
5F94
E
1
UNSIGNED_32
1000
DIx inversion
24461
5F8D
E
1
UNSIGNED_16
DOx inversion
24457
5F89
E
1
UNSIGNED_8
Motor overload threshold (I²xt)
24455
5F87
E
1
INTEGER_16
100
Initial value motor overload (I²xt)
24453
5F85
A
1
UNSIGNED_16
100
Device utilisat. threshold (Ixt)
24452
5F84
E
1
INTEGER_16
100
Ramp smoothing - main setpoint
24441
5F79
E
1
UNSIGNED_8
1
Device state
24438
5F76
E
1
UNSIGNED_16
1
Device settings
24434
5F72
A
1
UNSIGNED_8
1
Auto-start option
24433
5F71
E
1
UNSIGNED_8
Switching frequency reduction (temp.)
24431
5F6F
E
1
UNSIGNED_8
1
Status word
24425
5F69
E
1
UNSIGNED_16
Status word 2
24420
5F64
E
1
UNSIGNED_16
Cause of controller inhibit
24417
5F61
E
1
UNSIGNED_16
Cause of quick stop QSP
24416
5F60
E
1
UNSIGNED_16
Error information
24410
5F5A
A
1
VISIBLE_STRING
Error information text
24409
5F59
A
3
VISIBLE_STRING
Code
Name
Index
Data
Access
dec
hex
DS
DA
DT
Factor
R
W
CINH