Oc6: i2xt motor overload, Error m, Oc6: i2xt overload motor" error message – Lenze 8400 BaseLine D User Manual
Page 159: Oc12: i2xt brake resistor overload, Xx.0125.00001, Xx.0123.00057, Xx.0123.00017, Xx.0123.00105, Xx.0123.00065, 8diagnostics & error management

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05
159
8
Diagnostics & error management
8.7
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
OC2: Power section - earth fault [xx.0123.00017]
ID1: Motor data identification error [xx.0123.00057]
OC12: I2xt overload - brake resistor [xx.0123.00065]
OC6: I2xt overload - motor [xx.0123.00105]
An01: AIN1_I < 4 mA [xx.0125.00001]
Response (Lenze setting printed in bold)
None Fault Trouble WarningLocked
Cause
Remedy
The device has recognised an earth fault at one of the
motor phases. To protect the device electronics, the in-
verter control is switched off.
• Mostly, incorrectly executed motor connections are
the cause.
• If motor filter, motor cable length, and cable type
(shielding capacity) are dimensioned incorrectly, this
error message may occur due to leakage currents to
PE.
• Check motor connections and the corresponding plug
connector on the device.
• Use motor filters, cable lengths, and cable types re-
commended by Lenze.
Response (Lenze setting printed in bold)
None Fault Trouble WarningLocked
Cause
Remedy
The device has detected an error during the motor data
identification.
Possible causes:
• Interrupted motor cable.
• Switched-off power section during the identification.
• Implausible start parameter settings.
• Check the motor connections and the corresponding
plug connector on the device and, if necessary, the
motor terminal box.
• Correct start parameters for the motor parameter
identification (motor nameplate data).
• Stable power supply of the device.
Response (Lenze setting printed in bold)
None Fault Trouble WarningLocked
Cause
Remedy
Too frequent and too long braking processes.
Check drive dimensioning.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None Fault Trouble WarningLocked
Cause
Remedy
Thermal overload of the motor.
• Observe load requirements.
• Correct dimensioning if necessary.
• In case of VFCplus operation: Check Vmin boost
(
).
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None Fault Trouble WarningLocked
Cause
Remedy
Open-circuit monitoring for analog input has tripped.
• Only if the analog input has been configured as a cur-
rent loop of 4 ... 20 (
= 2).
• Check wiring of the analog X4/A1U input terminal for
open circuit.
• Check connection of the external 250-Ω load resistor
between the terminals A1U and GND.
• Check minimum current values of the signal sources.