Drive application
7.3
Setting parameters (short overview)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.5.3
Terminals 11
7.5.4
Terminals 16
Connection
Assignment
Connection
Assignment
RFR
LA_NCtrl.bFailReset
A1U
LA_NCtrl.nMainSetValue_a
10 V ≡ 100 % reference speed (
)
DI1
LA_NCtrl.bSetSpeedCcw
DI2
LA_NCtrl.bSetDCBrake
DI3
LA_NCtrl.bMPotUp
NO, COM
LA_NCtrl.bDriveFail
DI4
LA_NCtrl.bMPotDown
DO1
LA_NCtrl.bDriveReady
X101
NO
COM
GND
A1U
AR
RFR
DI1
DI2
DI3
DI4
24E
DO1
12I
X4
+
Speed setpoint
Enable controller / reset error message
Direction of rotation CCw
Manual DC-injection braking (DCB)
increase speed
decrease speed
External supply 24 V DC
Motor potentiometer
DriveFail
DriveReady
Connection
Assignment
Connection
Assignment
RFR
LA_NCtrl.bFailReset
A1U
LA_NCtrl.nMainSetValue_a
10 V ≡ 100 % reference speed (
)
DI1
LA_NCtrl.bJogSpeed1
DI2
LA_NCtrl.bJogSpeed2
DI3
LA_NCtrl. bRLQCw
NO, COM
LA_NCtrl.bDriveFail
DI4
LA_NCtrl. bRLQCcw
DO1
LA_NCtrl.bDriveReady
X101
NO
COM
GND
A1U
AR
RFR
DI1
DI2
DI3
DI4
24E
DO1
12I
X4
+
Speed setpoint
Enable controller / reset error message
Selection of fixed setpoint 1/3
Selection of fixed setpoint 2/3
Cw rotation - quick stop
CCw rotation - quick stop
External supply 24 V DC
DriveFail
DriveReady