3 l_pctrl_1, L_pctrl_1, S controller – Lenze 8400 BaseLine D User Manual
Page 233: L_pctrl, 10 function library
Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05
233
10
Function library
10.3
L_PCTRL_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
10.3
L_PCTRL_1
This FB is a PID controller and can be used for various control tasks (e.g. as dancer position controller,
tension controller, or pressure controller).
The FB is provides with the following functions:
• Adjustable control algorithm (P, PI, PID)
• Ramp function generator for preventing setpoint step-changes at the input
• Limitation of the controller output
• Factorisation of the output signal
• Vp adaptation
• Integral action component can be switched off
Inputs
Identifier
Data type
Information/possible settings
nAdapt_a
INT
Adaptation of gain Vp set in
in percent
• Internal limitation to ± 199.9 %
• Changes can be done online.
nNSet_a
INT
Speed setpoint
• Scaling: 16384 ≡ 100 %
• Internal limitation to ± 199.9 %
nSet_a
INT
Sensor and process setpoint for operating modes 2, 4 and 5
• Scaling: 16384 ≡ 100 %
• Internal limitation to ± 199.9 %
nAct_a
INT
Speed or actual sensor value (actual process value)
• Scaling: 16384 ≡ 100 %
• Internal limitation to ± 199.9 %