C00091 | motor cosine phi, C00092 | motor magnetising inductance, C00093 | power section identification – Lenze 8400 BaseLine D User Manual

Page 185: C00094 | password, C00095 | motor magnetising current, C094, Passw, C091, C092, C095

background image

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

185

9

Parameter reference

9.2

Parameter list | C00091

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00091

C00092

C00093

C00094

C00095

Parameter | Name:

C00091 | Motor cosine phi

Data type: UNSIGNED_8

Index: 24484

d

= 5FA4

h

This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor

catalogue, the suitable value can be entered automatically.
Setting range

(min. value | unit | max. value)

Lenze setting

0.40

1.00 0.85

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00092 | Motor magnetising inductance

Data type: UNSIGNED_16

Index: 24483

d

= 5FA3

h

After the motor to be used has been selected from the motor catalogue, the suitable value can be entered automati-

cally. An automatic detection via the motor parameter identification is possible as well.
Setting range

(min. value | unit | max. value)

Lenze setting

0.0

mH

6500.0 0.0 mH

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00093 | Power section identification

Data type: UNSIGNED_16

Index: 24482

d

= 5FA2

h

Display of the identification of the detected power section of the controller
Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00094 | Password

Data type: INTEGER_32

Index: 24481

d

= 5FA1

h

The controller provides the opportunity to protect the menu level from unauthorised access by assigning a pass-

word.

Password protection

Setting range

(min. value | unit | max. value)

Lenze setting

0

9999 0

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00095 | Motor magnetising current

Data type: UNSIGNED_16

Index: 24480

d

= 5FA0

h

As of version 03.00.00

After the motor to be used has been selected from the motor catalogue, the suitable value can be entered automati-

cally. An automatic detection via the motor parameter identification is possible as well.
Display range

(min. value | unit | max. value)

0.00

A

99.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100