9
Parameter reference
9.2
Parameter list | C00105
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00105
C00106
C00107
Parameter | Name:
C00105 | Deceleration time quick stop
Data type: UNSIGNED_32
Index: 24470
d
= 5F96
h
The set deceleration time determines the ramp slope at quick stop
• When the output frequency falls below the threshold set in
, the DC injection brake DCB is activated.
Note:
The S-ramp time set in
is also active with quick stop!
In order to reach the required deceleration time for quick stop, set the time accordingly lower in this parameter.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
s
999.9 5.0 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00106 | Auto DCB: Hold time
Data type: UNSIGNED_32
Index: 24469
d
= 5F95
h
Hold time of the automatic DC injection brake
• The DC injection brake is applied for the time set here if the value falls below the speed setpoint set in
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
s
999.0 0.5 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00107 | DCB: Hold time
Data type: UNSIGNED_32
Index: 24468
d
= 5F94
h
Maximum hold time of the manual DC injection brake
• In order not to overload the motor thermally, a time for automatic switch-off of the DC injection brake can be set
here.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
s
999.0 999.0 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000