beautypg.com

C00105 | deceleration time quick stop, C00106 | auto dcb: hold time, C00107 | dcb: hold time – Lenze 8400 BaseLine D User Manual

Page 187: C105, C106, C107, Has expired, th, 9parameter reference

background image

Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05

187

9

Parameter reference

9.2

Parameter list | C00105

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00105

C00106

C00107

Parameter | Name:

C00105 | Deceleration time quick stop

Data type: UNSIGNED_32

Index: 24470

d

= 5F96

h

The set deceleration time determines the ramp slope at quick stop

• When the output frequency falls below the threshold set in

C00019

, the DC injection brake DCB is activated.

Note:

The S-ramp time set in

C00182

is also active with quick stop!

In order to reach the required deceleration time for quick stop, set the time accordingly lower in this parameter.
Setting range

(min. value | unit | max. value)

Lenze setting

0.0

s

999.9 5.0 s

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C00106 | Auto DCB: Hold time

Data type: UNSIGNED_32

Index: 24469

d

= 5F95

h

Hold time of the automatic DC injection brake

• The DC injection brake is applied for the time set here if the value falls below the speed setpoint set in

C00019

.

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

s

999.0 0.5 s

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C00107 | DCB: Hold time

Data type: UNSIGNED_32

Index: 24468

d

= 5F94

h

Maximum hold time of the manual DC injection brake

• In order not to overload the motor thermally, a time for automatic switch-off of the DC injection brake can be set

here.

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

s

999.0 999.0 s

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000