10
Function library
10.2
L_NSet_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter
10.2.1
Main setpoint path
• The signals in the main setpoint path are limited to a value range of ±32767.
• The signal at nNSet_a is first led via the JOG selection function.
• A selected JOG value switches the nNSet_a input inactive. Then, the subsequent signal conditio-
ning operates with the JOG value.
10.2.2
JOG setpoints
In addition to the direct main setpoint selection, via the input nNSet_a JOG setpoints can be set un-
der
.
• The JOG setpoints are binary-coded and can be called using the bJog1 and bJog8 selection in-
puts:
• The number of selection inputs to be assigned depends on the number of JOG setpoints re-
quired.
Parameter
Possible settings
Info
0.0
s
999.9 Acceleration time T
ir
for the main set-
point
• Lenze setting: 2.0 s
0.000
s
999.9 Deceleration time T
if
for the main
setpoint
• Lenze setting: 2.0 s
-199.9
%
199.9 Fixed setpoint 1 (JOG setpoint 1)
• Lenze setting: 40.0 %
-199.9
%
199.9 Fixed setpoint 2 (JOG setpoint 2)
• Lenze setting: 60.0 %
-199.9
%
199.9 Fixed setpoint 3 (JOG setpoint 3)
• Lenze setting: 80.0 %
Activates ramp rounding with PT1
behaviour for the main setpoint
• The corresponding S-ramp time
• Lenze setting: 0 (deactivated)
0 Off
1 PT1 behaviour
0.01
s
50.00 S-ramp time PT1
• Lenze setting: 20.00 s
Selection inputs
Used main setpoint
bJog2
bJog1
FALSE
FALSE
nNSet_a
FALSE
TRUE
TRUE
FALSE
TRUE
TRUE