10 function library – Lenze 8400 BaseLine D User Manual
Page 247
Lenze · 8400 BaseLine D · Reference manual · DMS 5.5 EN · 01/2014 · TD05
247
10
Function library
10.11
LS_DriveInterface
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Inputs
Identifier
DIS code | data type
Information/possible settings
bCInh
| BOOL
FALSE Enable controller: The controller switches to the "
device state, if no other source of a controller inhibit is active.
•
provides a bit coded representation of all active sour-
ces/triggers of a controller inhibit.
TRUE Inhibit controller (controller inhibit): The controller switches to the
" device state.
bFailReset
| BOOL
In the Lenze setting this input is connected to the digital input controller enable so
that a possibly existing error message is reset together with the controller enable (if
the cause for the fault is eliminated).
TRUE The current fault is reset, if the cause for the fault is eliminated.
• If the fault still exists, the error status remains unchanged.
bStatus_Bit0
bStatus_Bit2
bStatus_Bit3
bStatus_Bit4
bStatus_Bit5
bStatus_Bit14
bStatus_Bit15
| BOOL
Freely assignable bits in the status word of the controller.
Pre-assignment in the Lenze setting:
Bit0 - (Not connected)
Bit2 Current setpoint in the limitation
Bit3 Speed setpoint reached
Bit4 Actual speed value has reached the setpoint within one hysteresis
band
Bit5 Speed setpoint < comparison value (
Bit14 Current direction of rotation:
0 ≡ Clockwise rotation (Cw)
1 ≡ Counter-clockwise rotation (Ccw)
Bit15 Drive is ready for operation