Control channels, N o t e – ETC Unison Paradigm ACP Configuration Manual v2.1.2 User Manual
Page 57
3
Programming
52
Control Channels
The “Control Channel” menu provides the tools to display and change current architectural
control channel attribute output levels, view the current control arbitration, DMX and sACN
input and output addresses.
Adjustment of a channel attribute level from the Paradigm ACP is similar to applying control
from the LightDesigner programmer in Live Control. Levels are set to 0-100% or 0-255
depending on the type of channel attribute being controlled.
Step 1:
Scroll to select “Control Channels” from the “Arch Control” menu and press enter
(
). The “Select Space” menu list displays all spaces and subspaces
associated with control channels. Spaces are listed in alphabetical order.
Step 2:
Scroll to select the space containing the desired control channels and press enter
(
). Alternatively you may select
control channels within the selected space are listed including the current
intensity level. Control channels are sorted in alphabetical order.
Step 3:
Scroll to select the desired architectural control channel and press enter (
).
•
If the selected control channel has a single attribute, such as a dimmer, the properties
displayed for edit and status include only intensity. Additional status information
includes DMX port A and port B patching (e.g. 1B/127 is processor 1 port B address 1),
and sACN patching (e.g. 1/1 = universe 1, address 1).
Continue to step 4.a:
Step 4:
Edit the attribute level.
a: For a single control channel attribute, such as a dimmer, scroll to select the
new intensity level or use the button pad to specify an intensity level. Press
enter (
) to apply the level edit and return to the previous display or press
back ( ) to return to the previous display discarding the edit.
b: For a control channel with multiple attributes, such as a moving light, scroll
N o t e :
Displays may differ for architectural control channels with a single attribute versus
a channel with multiple attributes or parameters.
N o t e :
If arbitration is unique per channel attribute, “---” is displayed.
Intensity:
50%
Arb:
HTP with Priority
DMX in:
1A/1, 1A/127
DMX out:
1B/1, 1B/127
ACN out:
1/1
ACN in:
1/1
Chandelier 80%
Cyberlight 1
50%
Revolution 1
50%
Sconce wall 1
25%
Sconce wall 2
100%
Zone 1
50%
Zone 2
0%
Select Space
Atrium
Hall
Section 1
Section 2
Section 3
Section 4
Zone 1
Intensity:
50%
Pan:
0%
Tilt:
100%
Focus:
50%
Internal Media....
100%
Zoom:
80%
Control
Intensity:
50%
Arb:
HTP with Priority
DMX in:
1A/10
DMX out:
1B/10
ACN out:
1/10
ACN in:
1/10
Chandelier 80%
Cyberlight 1
50%
Revolution 1
50%
Sconce wall 1
25%
Sconce wall 2
100%
Zone 1
50%
Zone 2
0%
Revolution 1
Revolution 1
Intensity
•
If the selected control channel has multiple attributes, such as a moving light, all
attributes of the channel are listed for edit and status including intensity, pan, tilt, focus,
etc. The list of attributes match the attributes listed in the LightDesigner configuration.
Continue to step 4.b: