beautypg.com

Control channels, N o t e – ETC Unison Paradigm ACP Configuration Manual v2.1.2 User Manual

Page 57

background image

3

Programming

52

Control Channels

The “Control Channel” menu provides the tools to display and change current architectural

control channel attribute output levels, view the current control arbitration, DMX and sACN

input and output addresses.

Adjustment of a channel attribute level from the Paradigm ACP is similar to applying control

from the LightDesigner programmer in Live Control. Levels are set to 0-100% or 0-255

depending on the type of channel attribute being controlled.

Step 1:

Scroll to select “Control Channels” from the “Arch Control” menu and press enter
(

). The “Select Space” menu list displays all spaces and subspaces

associated with control channels. Spaces are listed in alphabetical order.

Step 2:

Scroll to select the space containing the desired control channels and press enter
(

). Alternatively you may select to display all channels in all spaces. All

control channels within the selected space are listed including the current

intensity level. Control channels are sorted in alphabetical order.

Step 3:

Scroll to select the desired architectural control channel and press enter (

).

If the selected control channel has a single attribute, such as a dimmer, the properties
displayed for edit and status include only intensity. Additional status information
includes DMX port A and port B patching (e.g. 1B/127 is processor 1 port B address 1),
and sACN patching (e.g. 1/1 = universe 1, address 1).
Continue to step 4.a:

Step 4:

Edit the attribute level.
a: For a single control channel attribute, such as a dimmer, scroll to select the

new intensity level or use the button pad to specify an intensity level. Press
enter (

) to apply the level edit and return to the previous display or press

back ( ) to return to the previous display discarding the edit.

b: For a control channel with multiple attributes, such as a moving light, scroll

N o t e :

Displays may differ for architectural control channels with a single attribute versus

a channel with multiple attributes or parameters.

N o t e :

If arbitration is unique per channel attribute, “---” is displayed.

Intensity:

50%

Arb:

HTP with Priority

DMX in:

1A/1, 1A/127

DMX out:

1B/1, 1B/127

ACN out:

1/1

ACN in:

1/1

Channels

Chandelier 80%
Cyberlight 1

50%

Revolution 1

50%

Sconce wall 1

25%

Sconce wall 2

100%

Zone 1

50%

Zone 2

0%

Select Space

Atrium
Hall
Section 1
Section 2
Section 3
Section 4

Zone 1

Intensity:

50%

Pan:

0%

Tilt:

100%

Focus:

50%

Internal Media....

100%

Zoom:

80%

Control

Intensity:

50%

Arb:

HTP with Priority

DMX in:

1A/10

DMX out:

1B/10

ACN out:

1/10

ACN in:

1/10

Channels

Chandelier 80%
Cyberlight 1

50%

Revolution 1

50%

Sconce wall 1

25%

Sconce wall 2

100%

Zone 1

50%

Zone 2

0%

Revolution 1

Revolution 1
Intensity

If the selected control channel has multiple attributes, such as a moving light, all
attributes of the channel are listed for edit and status including intensity, pan, tilt, focus,
etc. The list of attributes match the attributes listed in the LightDesigner configuration.
Continue to step 4.b: