ETC Unison DRd with Paradigm Control Termination Kit User Manual

E t c, Paradigm drd termination kit installation, Overview

background image

E T C

®

S e t u p G u i d e

Paradigm DRd Termination Kit Installation

Paradigm DRd Termination Kit Setup Guide

Page 1 of 2

Electronic Theatre Controls, Inc.

Corporate Headquarters

„

3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA

„

Tel +608 831 4116

„

Fax +608 836 1736

London, UK

„

Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK

„

Tel +44 (0)20 8896 1000

„

Fax +44 (0)20 8896 2000

Rome, IT

„

Via Ennio Quirino Visconti, 11, 00193 Rome, Italy

„

Tel +39 (06) 32 111 683

„

Fax+44 (0)20 8896 2000

Holzkirchen, DE

„

Ohmstrasse 3, 83607 Holzkirchen, Germany

„

Tel +49 (80 24) 47 00-0

„

Fax +49 (80 24) 47 00-3 00

Hong Kong

„

Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong

„

Tel +852 2799 1220

„

Fax +852 2799 9325

Service: (Americas)

[email protected]

„

(UK)

[email protected]

„

(DE)

[email protected]

„

(Asia)

[email protected]

Web:

www.etcconnect.com

„

Copyright © 2008 ETC. All Rights Reserved.

„

Product information and specifications subject to change.

7182M2230

„

Rev A

„

Released 09/2008

Overview

The Paradigm DRd termination kit (P-DRd-TK) is provided for field installation into a DRd enclosure for
use with a Paradigm architectural control processor. This kit includes the DRd left I/O board.

The left I/O board should be installed by the installing contractor or qualified field technician.

Installation

N o t e :

All low voltage control cables must run in separate conduit from power wires.

N o t e :

Data terminations to the left I/O board are specific to use with the Paradigm

architectural control processor (P-ACP) and are not compatible with an installed

SmartLink architectural control processor (S-ACP).

NO4

COM4

NO3

COM3

NO2

COM2

NO1

COM1

IN4

GND

IN3

GND

IN2

GND

IN1

GND

M1

M2

OUTPUTS

INPUTS

J4

J5

7183B4605 REV

© 2008 ETC, INC.

MADE IN THE U.S.A.

M4

RS-232

J3

C2

C3

C4

CR1

CR2

CR3

CR4

CR5

J2

M3

ETHERNET

1

6

The left I/O board supports the Paradigm architectural
control processor data terminations including:

• RS-232 on a male 9 pin (D style) connector

• Ethernet on a RJ-45 female connector

• Contact closure input terminations on a 8 pin

pluggable connector. Terminations available for 4
inputs and 4 ground wires.

• Contact closure output terminations on a 8 pin

pluggable connector. Terminations available for 4
normally open relay outputs and 4 common wires.

Step 1:

Align the left I/O board to the mounting

pems on the left side of the DRd enclosure.

Step 2:

Secure with the screws provided.