ETC Unison DRd with Paradigm Control Termination Kit User Manual
E t c, Paradigm drd termination kit installation, Overview
E T C
®
S e t u p G u i d e
Paradigm DRd Termination Kit Installation
Paradigm DRd Termination Kit Setup Guide
Page 1 of 2
Electronic Theatre Controls, Inc.
Corporate Headquarters
3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA
Tel +608 831 4116
Fax +608 836 1736
London, UK
Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK
Tel +44 (0)20 8896 1000
Fax +44 (0)20 8896 2000
Rome, IT
Via Ennio Quirino Visconti, 11, 00193 Rome, Italy
Tel +39 (06) 32 111 683
Fax+44 (0)20 8896 2000
Holzkirchen, DE
Ohmstrasse 3, 83607 Holzkirchen, Germany
Tel +49 (80 24) 47 00-0
Fax +49 (80 24) 47 00-3 00
Hong Kong
Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong
Tel +852 2799 1220
Fax +852 2799 9325
Service: (Americas)
(UK)
(DE)
(Asia)
Web:
Copyright © 2008 ETC. All Rights Reserved.
Product information and specifications subject to change.
7182M2230
Rev A
Released 09/2008
Overview
The Paradigm DRd termination kit (P-DRd-TK) is provided for field installation into a DRd enclosure for
use with a Paradigm architectural control processor. This kit includes the DRd left I/O board.
The left I/O board should be installed by the installing contractor or qualified field technician.
Installation
N o t e :
All low voltage control cables must run in separate conduit from power wires.
N o t e :
Data terminations to the left I/O board are specific to use with the Paradigm
architectural control processor (P-ACP) and are not compatible with an installed
SmartLink architectural control processor (S-ACP).
NO4
COM4
NO3
COM3
NO2
COM2
NO1
COM1
IN4
GND
IN3
GND
IN2
GND
IN1
GND
M1
M2
OUTPUTS
INPUTS
J4
J5
7183B4605 REV
© 2008 ETC, INC.
MADE IN THE U.S.A.
M4
RS-232
J3
C2
C3
C4
CR1
CR2
CR3
CR4
CR5
J2
M3
ETHERNET
1
6
The left I/O board supports the Paradigm architectural
control processor data terminations including:
• RS-232 on a male 9 pin (D style) connector
• Ethernet on a RJ-45 female connector
• Contact closure input terminations on a 8 pin
pluggable connector. Terminations available for 4
inputs and 4 ground wires.
• Contact closure output terminations on a 8 pin
pluggable connector. Terminations available for 4
normally open relay outputs and 4 common wires.
Step 1:
Align the left I/O board to the mounting
pems on the left side of the DRd enclosure.