ETC Unison Paradigm Handheld Docking Station User Manual
E t c, Unison paradigm, Docking station
E T C
®
S e t u p G u i d e
Unison Paradigm
®
Docking Station
Unison Paradigm Docking Station Setup Guide
Page 1 of 3
Electronic Theatre Controls, Inc.
Corporate Headquarters
3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA
Tel +608 831 4116
Fax +608 836 1736
London, UK
Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK
Tel +44 (0)20 8896 1000
Fax +44 (0)20 8896 2000
Rome, IT
Via Pieve Torina, 48, 00156 Rome, Italy
Tel +39 (06) 32 111 683
Fax +44 (0) 20 8752 8486
Holzkirchen, DE
Ohmstrasse 3, 83607 Holzkirchen, Germany
Tel +49 (80 24) 47 00-0
Fax +49 (80 24) 47 00-3 00
Hong Kong
Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong
Tel +852 2799 1220
Fax +852 2799 9325
Service: (Americas)
(UK)
(DE)
(Asia)
Web:
Copyright © 2013 ETC. All Rights Reserved.
Product information and specifications subject to change.
7184M2240
Rev A
Released 2013-10
ETC intends this document to be provided in its entirety.
Overview
The Unison Paradigm
®
Docking Station (P-LCD-DOCK) connects to the Paradigm lighting control
network using NetConnect and serves the Paradigm Handheld Touchscreen as both a charging station
and as a wireless interface for MeshConnect communications.
Buttons and Indicators
• RX and TX indicators - flashes when the Docking Station sends (TX) or receives (RX) a wireless
communication.
• Reset button - when pressed resets the Docking Station. After reboot, any Handheld that is
connected to the Docking Station will reload the configuration.
• Power indicator - illuminates solid when power is connected.
NetConnect
NetConnect uses Power over Ethernet (IEEE 802.3af) communications to connect between the
Paradigm Docking Station and the Paradigm Architectural Control Processor (P-ACP).
A 12V DC power input adapter is supplied and can be used when Power over Ethernet is not available.
MeshConnect
MeshConnect is the wireless control network used with the Paradigm Handheld Touchscreen for
communication with a Docking Station and/or Wireless Access Station.
N o t e :
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
Rx
Tx
Reset Pwr
MeshConnect
antenna
RX and TX
indicators
DC Power input
12V Input
Lock
NetConnect
Adjustable
Cradle
Reset button,