Module type, N o t e – ETC Unison Paradigm ACP Configuration Manual v2.1.2 User Manual
Page 36
31
Paradigm Architectural Control Processor Configuration Manual
Step 4:
To maintain individual dimmer settings, press (
) again. To change the ending
number and select a range of dimmers, use the touch wheel or the alpha-numeric
button pad to change the ending number.
Step 5:
Press enter (
) to change focus back to “From dimmer”.
Module Type
:
Step 1:
Use the touch wheel to scroll down to “Module Type” and press enter (
). The
“Module Type” menu will display all possible dimmer module types available for
the rack and voltage selection.
Step 2:
Scroll down the module list and press enter (
) to select a module type.
Changing a module type defaults all dimmer properties for the specified
dimmer(s). Reference
dimmer properties and their defaults.
Step 3:
You can change dimmer properties from their default by using the touch wheel
to scroll down to “Mode” and press enter (
). A full list of dimmer modes will
display.
•
Changing the dimmer firing mode automatically changes the default settings
for curve, threshold, voltage regulation, minimum voltage and maximum
voltage.
See “Dimmer Properties” on page 92.
Step 4:
Scroll the list and press enter (
) to select a new mode. Reference
on
for a complete listing of the available modes and their
defaults.
N o t e :
When specifying a range of dimmers, those properties that are not equal among
the selected dimmers will display as empty property fields. Any edits made to the
empty property fields are applied to the entire selected range of dimmers.
Specifying a different module type defaults all dimmer properties for the selected
range.
N o t e :
Changing the module type field to dimmers that do not have dual dimmers (e.g.
fluorescent, constant circuit, and air flow modules) do not display values for
properties or allow edits to dimmer properties.
N o t e :
Module types available for selection are dependent on the rack input voltage,
either 120 VAC, 230 and 240 VAC, or 277 VAC. Reference
.
Module Type
AFM
CC15
CC20
D15
D15E
D15F
D20
D20E
D20F
ELV10
L10
L10F
R15
R20
Module Type
This graphic represents
the 120 VAC module list.
Dimmer Setup
From dimmer:
1 to: 3
Module Type:
D20
Curve:
Mod
Sq
Threshold: 0%
Voltage Reg:
On
Max
Scale:
118V
Mode:
Normal
Each module type has a default set of properties such as the
firing mode, dimmer curve, etc. When changing a module
type, all dimmer properties for the specified dimmer(s) also
change to match the new module type property defaults. You
may edit the properties to your desired values.