DRd Semi-Recessed Installation Kit

DRd Semi-Recessed Installation Kit Installation Guide

Page 1 of 8

Electronic Theatre Controls, Inc.

Corporate Headquarters

3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA

Tel +608 831 4116

Fax +608 836 1736

London, UK

Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK

Tel +44 (0)20 8896 1000

Fax +44 (0)20 8896 2000

Rome, IT

Via Pieve Torina, 48, 00156 Rome, Italy

Tel +39 (06) 32 111 683

Fax +44 (0) 20 8752 8486

Holzkirchen, DE

Ohmstrasse 3, 83607 Holzkirchen, Germany

Tel +49 (80 24) 47 00-0

Fax +49 (80 24) 47 00-3 00

Hong Kong

Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong

Tel +852 2799 1220

Fax +852 2799 9325

Service: (Americas)

[email protected]

(UK)

[email protected]

(DE)

[email protected]

(Asia)

[email protected]

Web:

www.etcconnect.com

Copyright © 2012 ETC. All Rights Reserved.

Product information and specifications subject to change.

7183M2120

Rev A

Released 2012-02



ETC intends this document to be provided in its entirety.

Using this Guide

This document is intended to guide you through the installation of the DRd Semi-Recessed installation
kit. Reference the Unison DRd Rack Enclosure Installation Manual for instructions that are specific to
the installation of the DRd rack including conduit entry, wire specification and termination, installing rack
options, checking the rack installation, sealing air leaks, etc.

Return to this guide to finish up the installation including setting the fan speed switch on the dimming
engine, re-attaching the DRd rack door, and attaching the cover.

Overview

The Unison DRd Semi-Recessed installation kit provides the ability to partially recess a Unison DRd
rack enclosure into a wall.

Two kits are available:

Each kit ships with the following:

• rough-in enclosure with extension rails attached (rails are removable as needed)
• cover
• hardware including:

4 each 5/16 nuts and washers to attach the DRd rack

8 each 10-32 screws to attach the cover

• this installation guide

Model

Part Number

Description

DRd6-RIK

7183K1003

DRd 6 Semi-Recessed Installation kit

DRd12-RIK

7183K1002

DRd 12 Semi-Recessed Installation kit

Rough-in enclosure

The enclosure installs into the cavity of a wall and

secures directly to 2”x4” or 2”x6” construction.

The installation depth of the rough-in determines

how much the DRd rack will extend from the

finished surface.
Openings are provided on the rough-in enclosure,

matching the top and bottom acceptable wire

access for the DRd enclosure, allowing for

convenient conduit access and wire routing.

Extension rails (removable)

Extension rails are provided to extend the enclosure (up

to additional 2.5 inches) flush to the finished wall surface

(as required) for cover attachment. These rails can be

easily removed when they are not required.

Cover

The cover is provided to fit securely to the rough-in

enclosure or extension rails as needed. When the DRd rack

enclosure is installed with a Unison Battery Pack (UBPO), a

knockout is provided in the cover for removal as needed.