I n s t a l l a t i o n G u i d e

Unison

®

EchoConnect Cat5 Station Termination Kit

EchoConnect Cat5 Station Termination

Page 1 of 1

Electronic Theatre Controls, Inc.

Corporate Headquarters

3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA

Tel +608 831 4116

Fax +608 836 1736

London, UK

Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK

Tel +44 (0)20 8896 1000

Fax +44 (0)20 8896 2000

Rome, IT

Via Pieve Torina, 48, 00156 Rome, Italy

Tel +39 (06) 32 111 683

Fax +44 (0) 20 8752 8486

Holzkirchen, DE

Ohmstrasse 3, 83607 Holzkirchen, Germany

Tel +49 (80 24) 47 00-0

Fax +49 (80 24) 47 00-3 00

Hong Kong

Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong

Tel +852 2799 1220

Fax +852 2799 9325

Service: (Americas)

[email protected]

(UK)

[email protected]

(DE)

[email protected]

(Asia)

[email protected]

Web:

www.etcconnect.com

Copyright © 2014 ETC. All Rights Reserved.

Product information and specifications subject to change.

7186M2150

Rev A

Released 2014-05

ETC intends this document to be provided in its entirety.

Overview

The EchoConnect Cat5 station termination kit facilitates termination of Category 5 (or equivalent) cable on the
EchoConnect communication bus. ETC recommends using Belden 1583A (or approved equal) wire. The total
combined length of an EchoConnect wire run using Cat5 may not exceed 1,000 feet (305m).

The included Cat5 termination board includes a Cat5 input and optionally a Cat5 through connection, as well as a
two pin screw terminal for connection between the Cat5 termination board and a Unison Echo

®

control station.

Installation

Step 1:

Refer to the provided Cat5 Cable Preparation for IDC Termination Setup Guide to prepare the Cat5
cable for termination to the Cat5 station termination board.

Step 2:

Connect the ESD ground wire pigtail.
a: Strip 3/8” (9-10mm) of insulation from the bare end of the ground wire pigtail and the Echo

control station ground wire.

b: Use one WAGO connector, provided in the Echo station installation kit, to connect the station

ESD ground pigtail and the Cat5 termination board ESD ground pigtail. Open two terminal levers
on the WAGO connector and insert each ground wire into a terminal.

c: Close the levers onto the wires.
d: Install the Faston connector to the spade terminal on the Cat5 termination board.

Step 3:

Connect EchoConnect wiring.
a: Strip 3/8” (9-10mm) of insulation from the bare end of the EchoConnect power pigtail (provided

with the station).

b: Loosen the two screw terminals on the Cat5 termination board.
c: Insert the white wire (typical) into terminal 1 (identified with a + symbol and an arrow on the

board) and the black wire the remaining terminal.

d: Secure the screws firmly onto each wire.
e: Connect the other end of the EchoConnect pigtail (two pin connector) to the two pin receptacle

on the Echo station.

Step 4:

Connect the Cat5 input connector (and optionally the output connector) to the Cat5 termination
board.
a: Connect the IDC connector with prepared data input cable from the station to the Cat5

receptacle on the Cat5 termination board.

b: Connect the IDC connector with prepared output cable to the remaining Cat5 receptacle on the

Cat5 termination board.

Step 5:

Remove the protective backing off the mounting tape and secure the termination board to the inside
of the station junction box.

N o t e :

The connector referenced in Step 4 of the Cat5 Cable Preparation for IDC Termination Setup

Guide is the 8-position connector (J3409-F) provided in this termination kit.

This kit includes the following:

• Cat5 station termination board
• One ESD ground wire pigtail with a Faston connector attached
• 2 each 8 position female IDC connectors (J3409-F)
• 3 each cable ties
• Cat5 Cable Preparation for IDC Termination Setup Guide (4100M2202)