beautypg.com

Quick rack setup, Voltage l-n, Rack type – ETC Unison Paradigm ACP Configuration Manual v2.1.2 User Manual

Page 44: Module type

background image

39

Paradigm Architectural Control Processor Configuration Manual

Quick Rack Setup

The “Quick Rack Setup” menu provides you with easy access to the most important dimmer

rack properties. Voltage, rack type, and temperature settings are automatic settings (Auto)

made by the Paradigm ACP. Notice also that rack property defaults have already been

made for you and are indicated in the default menu. You may change any of these settings.

When changing a value, an asterisk “*” will display next to the changed value. When you

have made all value adjustments desired, scroll to the bottom of the menu. Select “Apply

Changes * Only” to save only the changes (indicated with an asterisk*) or select “Apply All”

to save all of the settings in the “Quick Rack Setup” menu.

Voltage L-N

This setting is automatically detected by the Paradigm ACP and should not need to be

changed. These settings include 100-130, 220-240, and 277 VAC.

Step 1:

Use the touch wheel to scroll to “Voltage L-N”, press enter (

) repeatedly to

cycle through the available options.

Step 2:

When the desired value is displayed, use the touch wheel to scroll to the next
setup option or scroll to “Apply Changes Only” or “Apply All”. Press enter (

) to

select.

Rack Type

This setting is automatically detected by the Paradigm ACP and should not need to be

changed. These settings include DRd6, DRd12 and DRd24.

Step 1:

Use the touch wheel to scroll to “Rack Type”, press enter (

) repeatedly to

cycle through the available options.

Step 2:

When the desired value is displayed, use the touch wheel to scroll to the next
setup option or scroll to “Apply Changes Only” or “Apply All”. Press enter (

) to

select.

Module Type

Module type allows you to quickly set all dimmers in the DRd rack to a single type. Available

modules are determined by the voltage which is normally automatically determined.

Reference

“Dimmer Specifications”, page 83

for dimmer module property defaults.

For a 100-130 VAC dimmer rack, the default is a D20 dimmer module.

For a 230-240 VAC dimmer rack, the default is an ED15 dimmer module.

For a 277 VAC dimmer rack, the default is an AD20 dimmer module.

Step 1:

Use the touch wheel to scroll to “Module Type”, press enter (

). The module

type menu list displays for selection.

Step 2:

Use the touch wheel to scroll the module type list, press enter (

) to make your

selection.

C A U T I O N :

Use extreme caution when adjusting settings that default to “Auto” as these affect

important aspects of your dimming configuration. For example, the voltage setting

determines which dimmer modules are available for selection.

Quick Rack Setup

Voltage L-N

Auto

Rack Type:

Auto

Module Type:

D20

Balance:

Straight

DMX Start Addr:

1

Temp:

Fahrenheit

Apply Changes* Only

Quick Rack Setup

Rack Type:

Auto

Module Type:

D20

Balance:

Straight

DMX Start Addr:

1

Temp:

Fahrenheit

Apply Changes* Only

Apply All