E T C

®

I n s t a l l a t i o n G u i d e

Unison

®

EchoConnect Cat5 Termination Box

EchoConnect Cat5 Termination Box

Page 1 of 2

Electronic Theatre Controls, Inc.

Corporate Headquarters

3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA

Tel +608 831 4116

Fax +608 836 1736

London, UK

Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK

Tel +44 (0)20 8896 1000

Fax +44 (0)20 8896 2000

Rome, IT

Via Pieve Torina, 48, 00156 Rome, Italy

Tel +39 (06) 32 111 683

Fax +44 (0) 20 8752 8486

Holzkirchen, DE

Ohmstrasse 3, 83607 Holzkirchen, Germany

Tel +49 (80 24) 47 00-0

Fax +49 (80 24) 47 00-3 00

Hong Kong

Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong

Tel +852 2799 1220

Fax +852 2799 9325

Service: (Americas)

[email protected]

(UK)

[email protected]

(DE)

[email protected]

(Asia)

[email protected]

Web:

www.etcconnect.com

Copyright © 2014 ETC. All Rights Reserved.

Product information and specifications subject to change.

7186M2130

Rev A

Released 2014-05

ETC intends this document to be provided in its entirety.

Overview

This EchoConnect Cat5 termination box is intended for installation on a wall
or flat vertical surface, typically near or directly next to a wall mount Echo
Station Power Supply.

Use the Unison EchoConnect Cat5 termination box to facilitate termination
of up to 16 runs of Category 5 (or equivalent) cable on the EchoConnect
communication bus.

The following supplies are included for installation convenience:

• 6 feet (1.8m) of Belden 8471 cable
• Six position screw terminal connector J3263-F (x1)

Rough-In Conduit and Wiring

Terminations include:

• EchoConnect (Belden 8471 twisted pair) installed between this Termination Box and the adjacent

Echo Station Power Supply. This wire pair is provided.

• Category 5 (or equivalent) cable installed between this Termination Box and each Echo Station

control run. Up to 16 runs of EchoConnect are supported.

• ESD ground wires are required between this Termination Box ground termination bar and any

Echo station that is not installed entirely in grounded metal conduit.

N o t e :

Follow all local codes and restrictions.

6’ (1.8m)
included

11.5”

292mm

4”

102mm

14”

356mm

3.15” deep

(80mm)

Mount Box to Wall

This box is provided with four knockouts on each long side, sharing the same
conduit entry locations as the wall mount Echo Station Power Supply. All wiring
terminations are accessible from the front with the cover removed. If you are
mounting this box directly next to the wall mount Echo Station Power Supply, use
appropriate attaching hardware and wire protection hardware (not provided).

Step 1:

Remove the six screws securing the front cover to the box.

Step 2:

Align the unit to the wall and mark the mounting keyholes.
Alternatively, reference the dimensioned drawing on the left.

Step 3:

Drill the mounting holes and install the mounting hardware (not
provided). Expose at least 3/4” (19mm) of threads for mounting the
unit.

Step 4:

Attach the termination box to the mounting hardware, where the
back side of the unit is flush to the wall, then tighten the mounting
hardware.