internal operating temperature - The internal operating temperature is measured and
displays on the dimming rack status display. By default, temperature is displayed in °F
when the rack is 120, 240, or 277 VAC, and in °C when the rack is 230 VAC.

rack software version - The rack software is specific to the dimming engine and may
differ from the ACP software version.

Arch Control Status Display

display title - A menu’s title appears in the first row of every display for easy navigation.

scroll to previous display - When the counter-clockwise symbol appears in the display

use the touch wheel to scroll counter-clockwise for the Dimming Rack Status display.

processor name - Prior to using configuration data with a Paradigm processor in a multi-

processor system, each processor must be configured as one of the 20 possible per

system.

See “Set Processor Identity and IP Address” on page 9.

processor IP address - In addition to assigning a processor name (id) the processor IP

address must also be assigned. Automatic IP address settings are used when the

processor name (identity) is unknown.

status message area - Status messages are common to both the dimming rack and ACP

status displays. When a system error is detected, the message changes to reflect the

specific error type. When multiple errors are detected, each error message cycles on the

display, first by severity and then by chronological occurrence. Reference

“Status / Error

Messages”

for a complete listing of possible errors and the actions required to clear them.

DMX A: Indicates DMX port configuration and activity.

DMX B: Indicates DMX port configuration and activity. When the Paradigm ACP is installed

in a host DRd enclosure, port B must be configured as an output and is always active.

rack type - Displays the host rack type. The Paradigm ACP automatically detects the rack

type as either an ERn, DRd6, DRd12, or DRd12AX12X.

software version - The ACP software is specific to the Paradigm Architectural Control

Processor and may differ in version number from the dimming engine software version.

Arch Control Status

Processor Name

IP: 10.101.10.101

System OK

DMX A:

In

Inactive

DMX B:

Out

Active

DRd12

v1.4.5