beautypg.com

ETC Echo Wall Mount Station Power Supply User Manual

E t c, Unison echo, Wall mount station power supply

background image

E T C

®

I n s t a l l a t i o n G u i d e

Unison Echo

®

Wall Mount Station Power Supply

Wall Mount Station Power Supply

Page 1 of 3

Electronic Theatre Controls, Inc.

Corporate Headquarters

3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA

Tel +608 831 4116

Fax +608 836 1736

London, UK

Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK

Tel +44 (0)20 8896 1000

Fax +44 (0)20 8896 2000

Rome, IT

Via Pieve Torina, 48, 00156 Rome, Italy

Tel +39 (06) 32 111 683

Fax +44 (0) 20 8752 8486

Holzkirchen, DE

Ohmstrasse 3, 83607 Holzkirchen, Germany

Tel +49 (80 24) 47 00-0

Fax +49 (80 24) 47 00-3 00

Hong Kong

Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong

Tel +852 2799 1220

Fax +852 2799 9325

Service: (Americas)

[email protected]

(UK)

[email protected]

(DE)

[email protected]

(Asia)

[email protected]

Web:

www.etcconnect.com

Copyright © 2014 ETC. All Rights Reserved.

Product information and specifications subject to change.

7186M2100

Rev A

Released 2014-06

ETC intends this document to be provided in its entirety.

Overview

Wall Mount Enclosure Installation

Mount the Unit to the Wall

Step 1:

Remove the front cover of the unit to

reveal the four mounting keyholes

from inside the unit.

Step 2:

Align the unit to the wall and mark the
mounting keyholes. Alternatively, use
the measured keyhole dimensions
located in the graphic (right) to mark
the hole locations for the mounting
hardware.

Step 3:

Drill the holes and install the mounting
hardware.

• Mounting hardware is not

supplied.

• Expose at least 1” (25mm) of

threads for mounting the unit.

Step 4:

Attach the unit to the mounting
hardware, where the back side of the
unit is flush to the wall, then tighten the
mounting hardware.

Step 5:

Insert a screw into the provided wall
anchor point, located between the left
side mounting keyholes of the unit. Populating this hole with a screw provides additional
security that the unit will not fall from the wall during a seismic condition.

The Echo Wall Mount Station Power Supply (E-SPM-WM) is
designed for use with the Echo control system to supply power
for up to 16 Echo control stations on the topology-free Echo
control network.

N o t e :

If you are using Cat5 (or Cat5e) wiring, an

external Echo Cat5 Termination Box (is

required. Contact ETC for ordering details.

Control wiring instructions between the

termination box and this Wall Mount Station

Power Supply will be provided with the Cat5

termination installation instructions.

10.5”

267mm

14”

356mm

insert seismic

condition screw

here

11.5”

292mm

8.7”

221mm

3.15” deep

80mm

as viewed from the back panel