beautypg.com

Festo Контроллер крайних положений SPC11 User Manual

Page 99

background image

4. Commissioning

4-41

Festo P.BE-SPC11-SYS-EN en 1406e

Switch-on reaction with use of an absolute path measuring system

Position of the moveable mass

Display

Status

Outside of positions P...

The moveable mass remains uncontrolled in the
taught position (P...). The SPC11 waits for the first
positioning task.

In end positions P.01...P.02

A positioning task to the appropriate end position is
generated and the moveable mass is then pressed
against that end position. The corresponding output
(O1 or O2) supplies a 1-signal.

Switch-on reaction with use of an incremental path measuring system

Position of the moveable mass

Display

Status

Unknown: reference travel
required

The moveable mass remains uncontrolled in the
taught position (P...). The SPC11 waits for starting
of reference travel to P.01 or P.02.